Wang Jiajun Hong Bin Wang Hongmei

The principle of partial discharge detection is that through partial bridged discharge under high voltage electric field, it detects the inner air-filled cavity of high-voltage insulators. And it is a nondestructive detection method based on discharge magnitude to judge the insulation quality. The detecting system that adopts the partial discharge detection is more rigorous than testing system ...

2017
Chunchuan Charles Xu Chengyin Liu

Partial discharge occurs a lot in shielded dielectric power cables. Partial discharge pulses are high-frequency electromagnetic waves that propagate in the shielded dielectric power cables. This chapter will study partial discharge propagation and detection in shielded dielectric power cables.

Journal: :IEEJ Transactions on Fundamentals and Materials 1975

Journal: :Metrology and Measurement Systems 2010

Journal: :Energies 2021

Phase resolved partial discharge patterns (PRPD) are routinely used to assess the condition of power transformers. In past, classification systems have been developed in order automate fault identification task. Most those work with assumption that only one source is active. reality, however, multiple PD sources can be active at same time. Hence, PRPD overlap and cannot separated easily, e.g., ...

Journal: :International Journal of Fuzzy Logic and Intelligent Systems 2005

Journal: :Energies 2023

One of the most common failures or breakdowns that can occur in high-voltage (HV) equipment is due to partial discharges (PDs). This occurs as a result inadequate insulation, aging, harsh environmental effects, manufacturing flaws. PD detection and recognition methods have gained growing attention seen great progress past decades. Radiometric are one investigated approaches their immunity elect...

2011
BOONRUANG MARUNGSRI

Artificial intelligent techniques have been widely used in high voltage insulation technology application. In this paper, the effectiveness of artificial intelligent technique to apply for pattern recognition and classification of Partial Discharge (PD) is presented. Partial discharge signal was generated and measured by using an artificial partial discharge source. Characteristics of PD signal...

2017
Min Liu Xin Liu Qiang Yao Yulong Miao

Pulses with different amplitudes occur when an inner partial discharge fault exists in SF6-gas-insulated DC high-voltage electrical equipment. SF6 decomposes following complex physical and chemical processes. Discussing and quantifying the mathematical relationship of pulse discharge quantities to SF6 decomposition component characteristics is helpful to evaluate and predict the insulation faul...