نتایج جستجو برای: percutaneous retrieval

تعداد نتایج: 138465  

Journal: :The Medical journal of Malaysia 1990
A S Sakijan R Zambahari Z Annuar O Yahya J Ali

A successful retrieval of a detached segment of a CVP catheter by percutaneous right transfemoral venous route, using a Dotter intravascular retriever basket, is reported. The procedure was monitored under fluoroscopy. Only local anaesthesia, which was infiltrated around the puncture site, was given to the patient. No significant complication was encountered. Successful retrieval of the detache...

2010
Pei-Ching huang Kar-Wai Lui Yung-Liang Wan

To evaluate the safety and effect iveness of percutaneous transvascular retr ieval of the dislodged port-A catheter using En snare system via femoral vein approach. From Feb. 2006 to Dec. 2008, percutaneous transvascular retrievals of 26 dislodged port-A catheters in 25 patients were done. All retrievals were performed with En snare system with or without pigtail catheters under fluoroscopic gu...

2016
Juan Peng Xiao-Ming Zhang Lin Yang Hao Xu Nan-Dong Miao Yong-Jun Ren Kang Liu Xu-Li Min Ke Yang Shi Yang Cheng Yang

Objective. To report the experience of a percutaneous technique for retrieving fractured peripherally inserted central catheter (PICC) segments migrating into the heart or the pulmonary artery. Method. From April 2013 to July 2015, we performed percutaneous retrieval of fractured PICC segments migrating into the heart or the pulmonary artery in five cancer patients who had undergone chemotherap...

Journal: :Catheterization and Cardiovascular Interventions 2004

Journal: :Annals of the National Academy of Medical Sciences. India 2023

Abstract Double J (DJ) stents are placed in patients with obstructive uropathy to relieve the obstruction. Curved ends prevent slippage or migration of stent. Antegrade into urinary bladder retrograde ureter common complications. Mode retrieval migrated depends upon location We present a case series four cases percutaneous snaring cephalad DJ pediatric patients.

2015
M Sureisen BB Tan YY Teo CC Wong

Breakage of the tip of the micropituitary forceps during spine surgery is a rare occurrence. Retrieval of the broken tip could be a challenge in minimally invasive surgeries due to limitation of access and retrieval instruments. We describe our experience in handling such a situation during percutaneous radiofrequency discectomy. The removal was attempted, without converting into open surgery, ...

2013
Prashant N Mohite Sachin A Kuthe Shrirang D Ranade Pravin P Kulkarni Anton Sabashnikov Aron F Popov

As the use of percutaneous intervention is increasing for the closure of the atrial septal defect, the procedure related complications are also on rise, migration of the device being most common. The migrated devices with failed percutaneous retrieval must be removed surgically under cardiopulmonary bypass. During establishment of cardiopulmonary bypass, the handling of heart may cause further ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید