Journal: :iranian journal of medical physics 0
m. t. bahreyni toosi professor, medical physics research center, bu-ali research institute, mashhad university of medical sciences, mashhad, iran. m. momen nezhad ph.d. student in medical physics, mashhad university of medical sciences, mashhad, iran h. saberi ph.d. student in medical physics, mashhad university of medical sciences, mashhad, iran m. h. bahreyni toosi professor, medical physics research center, bu-ali research institute, mashhad university of medical sciences, mashhad, iran. a. hashemian assistant professor, medical physics research center, bu-ali research institute, mashhad university of medical sciences, mashhad, iran. r. salek assistant professor, radiation oncology dept., imam reza hospital, mashhad university of medical sciences, mashhad, iran.

ntroduction:  monte  carlo  simulation  is  the  most  accurate  method  of  simulating  radiation  transport  and  predicting doses at different points of interest in radiotherapy. a great advantage of the monte carlo method  compared  to  the  deterministic  methods  is  the  ability  to  deal  accurately  with  any  complex  geometry.  its  disadvantage is the extremely long computing time r...

H. Gholamhoseinian, M. Momennezhad, M.T. Bahreyni Toosi, R. Sadeghi, Sh. Nasseri,

Background: The presence of a wedge filter in the beam trajectory can modify the beam quality and cause some changes in the dosimetry parameters which are usually difficult to be measured directly and accurately. Material and Methods: In this study the MCNP-4C Monte Carlo code was used to simulate the 9 MV photon beam generated by a linear accelerator. Upon getting a good agreement bet...

Mehran Yarahmadi, Otto A. Sauer Sonja Wegener

Purpose: To investigate the energy dependence/spectral sensitivity of silicon diodes designed for small-field dosimetry and obtain response factors (RFs) for arbitrary photon spectra using Monte Carlo (MC) simulations.   Methods: The EGSnrc user-code DOSRZnrc was used to calculate the dose deposition in water and in the active volume of a stereotactic diode f...

Objective: The aim of the present study is to simulate 6 MV and 18 MV photon beam energies of a Siemens Primus Plus medical linear accelerator (Linac) and to verify the simulation by comparing the results with the measured data.Methods: The main components of the head of Siemens Primus Plus linac were simulated using MCNPX Monte Carlo (MC) code. To verify the results, experimental data of perce...

Danial Seifi Makrani Tayyeb Pourfallah

Introduction: In the treatment of breast cancer, breast conserving surgery (BCS) and whole breast irradiation is a usual technique. The influence of lumpectomy boost following breast radiotherapy is apparent, but there are different delivery methods. This work intended to compare the dosimetric parameters of electron beams and photon beams for boosting irradiation in breast can...

Introduction: The present study evaluated the dosimetric comparison between 6MV flattened filter (FF) and flattening filter-free (FFF) photon beams in intensity-modulated radiation therapy (IMRT) technique for the treatment of glioblastoma (GBM) patients. Material and Methods: The present study was conducted on 10 patients with GBM previously...

ژورنال: سنجش و ایمنی پرتو 2014

During the radiation therapy with electron beam, due to electron interaction and scattering from structures of the head of the medical linear accelerator, unwanted photons are produced. The main contribution of the photon contamination is resulted from the various components of the medical linear accelerator on the way of the high energy electron beam, and few percent is due to the interaction ...

 Introduction: Monte Carlo method is often applied in radiation therapy as utilized in all the branches of science. An important requirement for successful radiotherapy is carefully examine the dose distribution specifications and decrease the difference between these features with experience to an acceptable level. In this study, the characteristics of 6, 15 and 20 MeV incident x-rays are prov...

Journal: :iranian journal of radiation research 0
a. mesbahi department of medical physics, medical school, tabriz university of medical sciences, tabriz, iran p. mehnati department of medical physics, medical school, tabriz university of medical sciences, tabriz, iran a. keshtkar department of medical physics, medical school, tabriz university of medical sciences, tabriz, iran

background: monte carlo method (mc) has played an important role in design and optimization of medical linacs head and beam modeling. the purpose of this study was to compare photon beam features of two commercial linacs, varian 21ex and elekta sl-25 using mcnp4c mc code. materials and methods: the 6mv photon beams of varian 21ex and elekta sl-25 linacs were simulated based on manufacturers pro...

2016
J. Ko I.-Y. Kim C. Kim D.-T. Kim J.-Y. Huang S. Shin

At third-generation light sources, the photon beam position stability is a critical issue for user experiments. In general, photon beam position monitors are developed to detect the real photon beam position, and the position is controlled by a feedback system in order to maintain the reference photon beam position. At Pohang Light Source II, a photon beam position stability of less than 1 µm r...