نتایج جستجو برای: pneumatic arm tourniquet

تعداد نتایج: 77205  

Journal: :The Journal of bone and joint surgery. American volume 2009
Shahryar Noordin James A McEwen John F Kragh Andrew Eisen Bassam A Masri

Higher levels of tourniquet pressure and higher pressure gradients beneath tourniquet cuffs are associated with a higher risk of nerve-related injury. Measurement of limb occlusion pressure can help to minimize tourniquet pressure levels and pressure gradients for individual patients and individual surgical procedures. Selective use of pneumatic, wider, and contoured tourniquet cuffs reduces to...

Journal: :British journal of anaesthesia 1996
J P Estebe A Le Naoures Y Malledant C Ecoffey

Twenty-six patients requiring orthopaedic surgery were anaesthetized and oesophageal and rectal temperature were monitored continuously. Twenty patients requiring a pneumatic tourniquet were allocated prospectively to one of two groups: passive group (Pg) with reflective insulation on all available skin surface (n = 10) and forced group (Fg), with active warming by a forced air system (n = 10)....

Journal: :AORN journal 2013
Rodney W Hicks Bonnie Denholm

Perioperative nurses are likely to encounter the use of pneumatic tourniquets in a variety of operative and invasive extremity procedures. Use of a pneumatic tourniquet offers an opportunity to obtain a near-bloodless surgical field; however, the use of tourniquets is not without risk. Unfavorable outcomes include pain, thrombotic events, nerve compression injuries, and disruption of skin integ...

Journal: :The Journal of bone and joint surgery. British volume 1985
G A Irving T D Noakes

The protective effect of local hypothermia was studied in pig's limbs made ischaemic by long, repeated application of a pneumatic tourniquet. Twenty-one Landrace pigs were anaesthetised on two separate occasions six days apart and a pneumatic tourniquet at 500 mmHg pressure was applied to the same forelimb for three and two hours respectively. Ten of the pigs had local hypothermia from cold gel...

Journal: :Annals of Surgery 1910

2010
Lúcio Honório de Carvalho Júnior Luiz Fernando Machado Soares Matheus Braga Jacques Gonçalves Tiago Pinto de Oliveira Gomes Juraci Rosa de Oliveira Mauro Gualberto Coelho Rogério Luciano dos Santos Marco Antônio Percope de Andrade Guilherme de Lima e Silva Eduardo Nilo Vasconcelos Novais

UNLABELLED To evaluate whether, by using an arthropump (irrigation equipment with pressure sensor), pneumatic tourniquet use could interfere with the duration of surgery, recovery of movement and joint volume in patients who underwent knee videoarthroscopy for partial meniscectomy. METHODS 103 patients divided randomly into two groups regarding use or nonuse of a pneumatic tourniquet were eva...

Journal: :The archives of bone and joint surgery 2016
Georgios I Drosos Georgios Kiziridis Cristina Aggelopoulou Dimitrios Galiatsatos George Anastassopoulos Athanasios Ververidis Konstantinos Kazakos

BACKGROUND The pneumatic tourniquet (PT) is routinely used in upper and lower limb operations by most orthopaedic surgeons. The silicone ring tourniquet (SRT) was introduced in clinical practice over the last decade. Clinical as well as comparative studies have been published in volunteers concerning its safety and efficacy. The aim of this study was to investigate the postoperative effect of t...

Journal: :Acta orthopaedica 2006
Charlotta Olivecrona Jan Tidermark Per Hamberg Sari Ponzer Claes Cederfjäll

BACKGROUND The use of a pneumatic tourniquet to obtain a bloodless field during a total knee arthroplasty (TKA) allows the surgeon to work with greater technical precision in a safe, clear environment. Despite the benefits of surgical tourniquets and many advances in tourniquet equipment, their use is not without risk and complications may still occur. The primary aim of this study was to deter...

Journal: :Middle East journal of anaesthesiology 2011
Nebahat Gulcu Bulut Kazim Karaaslan Kutay E Ozturan Husamettin Cakici Hasan Kocoglu

BACKGROUND In this prospective study we aimed at examining the effects of pneumatic tourniquet on intraocular pressure during elective knee surgery. METHOD Twenty patients undergoing elective knee surgery under general anesthesia with tracheal intubation were inluded the study. Anesthesia was induced with pentothal, rocuronium and fentanyl, then maintained with sevoflurane and nitrous oxide i...

Journal: :The Journal of bone and joint surgery. British volume 1986
R J Newman A Muirhead

An unusually wide pneumatic tourniquet has recently become available; we provide a simple formula for its use with a low but effective inflation pressure. A prospective, randomised and controlled trial in 600 lower limb and 150 upper limb operations is reported. The wide tourniquet (12.5 cm) was as effective at low pressure as was a conventional tourniquet (9 cm) inflated to significantly highe...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید