نتایج جستجو برای: polymer gel dosimeter

تعداد نتایج: 195878  

Journal: :BioImpacts : BI 2013
Farideh Pak Alireza Farajollahi Ali Movafaghi Alireza Naseri

INTRODUCTION At present, the polymer gel dosimeter is considered to be the best possible dosimeter for measuring 3-dimesional radiation dose distribution in radiotherapy. These gels are normally toxic; therefore, manufacturing, handling and discarding them require special attention. In order to find less toxic recipe, N-isopropyle acrylamide polymer gel (NIPAM) was introduced. In this study, th...

A.A. Mahmoud, A.A. Rahman, I.S. Mustafa, N.N.A Razak, N.Z. Yahaya, S. Kandaiya,

Background: An effective polymer gel dosimeter can be fabricated by varying the composition of its chemical components. Materials and Methods: The MAGAT gel dosimeter formulations that used different compositions of Methacrylic acid (MAA) and gelatin were extensively investigated in the present study according to the R2–dose response and R2–dose sensitivity. The irradiation of M...

Ahmad Mostaar, Mohammad Houshyari Saeede Amiri

Introduction: In radiotherapy, treatment planning methods are evaluating and transforming every day, so precision in calculation and determination of dose delivery process is performing more important role in radiotherapy than past. In modern radiotherapy treatments, deramatically increase of small fields utilization, causes the polymeric gels has known as the most reliable dos...

2011
K. Adinehvand B. Azadbakht

The purpose of this study was to evaluate dependence of MAGICA polymer gel dosimeter 1/T2 on different electron energies as well as on different mean dose rates for a standard clinically used Linear accelerator. A calibration curve (in the linear region) based on 12 dosimeters (11 irradiated and one background) was obtained for 6MeV electron beam. Dose rate of dependence was studied in 10MeV el...

Journal: :journal of biomedical physics and engineering 0
m. mahdavi ph.d, physics depart- ment, mazandaran uni- versity, babolsar, iran m. khadem-abolfazli m.sc, para medical de- partment, babol univer- sity of medical sciences, babol, iran s. r. m. mahdavi ph.d, medical physics department, tehran university of medical sci- ences, tehran, iran gh. ataei m.sc, para medical de- partment, babol univer- sity of medical sciences, babol, iran

background: radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like phantom developed to date. objective: the aim of this study is an investigating of percentage depth dose enhancement within the gel medium with used of conformal distribution gold nanoparticle as contrast agents by high atomic number material. methods: in this work...

Ghorban Safaeian, Mina Nouri, Mohammad Hosein Bahreyni Toossi Mohammad Taghi Bahreyni Toossi Shahram Bayani

Introduction: The objective of this work is to study the ability of MRI normoxic polymer gel dosimetry system to be used to verify the calculated dose distribution, in a simple geometry, in clinical radiotherapy. Materials and Methods:  Initially, 2 liters of the normoxic MAGAT polymer gel was prepared and then poured into two cylindrical Perspex phantom (simu...

Journal: :iranian journal of medical physics 0
tayeb allahverdi pourfallah biochemistry and biophysics dept., faculty of medicine, mazandaran university of medical sciences, sari, iran

introduction polymer gel dosimeters offer a practical solution to 3d dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. in this study, egsnrc calculated and pagat polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of gamma knife in homogeneous and inhomogeneous phantoms were compared with eac...

2017
Heather M Whitney Daniel F Gochberg C Waldenberg A Karlsson Hauer

The normoxic polymer gel dosimeter based on N-isopropyl acrylamide (NiPAM) is a promising full 3D-dosimeter with high spatial resolution and near tissue equivalency. NiPAM gel samples were irradiated to different doses using a linear accelerator. The absorbed dose was evaluated using MRI and statistical significance of the analysed data was calculated. The analysis was carried out using an in-h...

2011
B. Azadbakht

Background: The purpose of this study was to determine the percentage depth dose (PDD) of PAGAT normoxic polymer gel dosimeter by electron beams using MRI technique for a standard clinically used Co-60 therapy unit and an electa linear accelerator. Materials and Methods: Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2(1/T2) was determined to be 4.5% N,...

2011
Timothy Olding Oliver Holmes Paul DeJean Kim B. McAuley Ken Nkongchu Giles Santyr L. John Schreiner

This paper explores the combination of cone beam optical computed tomography with an N-isopropylacrylamide (NIPAM)-based polymer gel dosimeter for three-dimensional dose imaging of small field deliveries. Initial investigations indicate that cone beam optical imaging of polymer gels is complicated by scattered stray light perturbation. This can lead to significant dosimetry failures in comparis...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید