نتایج جستجو برای: polymer gel treatment

تعداد نتایج: 1570732  

Journal: :iranian journal of medical physics 0
asghar mesbahi medical physics department, faculty of medicine, tabriz university of medical sciences, tabriz, iran. radiation oncology department, imam hospital, tabriz, iran

introduction the purpose of the current study was to determine optical sensitivity of n-isopropyl acrylamide nipam and polyacrylamide gelatin and tetrakis hydroxymethyl phosphoniun chloride (pagat) polymer gels for different wavelength of visible light spectrum applied in optical computed tomography method. materials and methods nipam and pagat polymer gels with conventional formulations used f...

Journal: :iranian journal of medical physics 0
hadis ansari mehr1 department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran

introduction the use of cut-outs in electron applicators make changes on output, isodose, and percentage depth dose (pdd) curves. these changes and electron beam dose distribution in the form of three-dimensional (3d) can be measured by gel dosimeters. materials and methods dosimetry was performed with and without a square shield (6×6 cm2 field). the energies were 4, 9, and 16 mev and phantom w...

Ahmad Mostaar, Mohammad Houshyari Saeede Amiri

Introduction: In radiotherapy, treatment planning methods are evaluating and transforming every day, so precision in calculation and determination of dose delivery process is performing more important role in radiotherapy than past. In modern radiotherapy treatments, deramatically increase of small fields utilization, causes the polymeric gels has known as the most reliable dos...

Journal: :Journal of Physics: Conference Series 2009

Journal: :iranian journal of radiation research 0
a.r. farajollahi department of medical physics, faculty of medicine, tabriz university of medical sciences, tabriz, iran f. pak department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran m. horsfield department of cardiovascular sciences, university of leicester, leicester royal infirmary, leicester, uk z. myabi department of radiology, emam reza teaching hospital, tabriz university of medical sciences, tabriz, iran

background: in this study the basic radiation properties of n-isopropylacrylamaide polymer gel dosimeter were determined together with verification of its soft tissue equivalency. materials and methods: the nipam gel was prepared and irradiated approximately 2 h after manufacturing. the magnetic resonance (mr) images were made 24 h after irradiation. the nuclear magnetic resonance (nmr) respons...

Journal: :iranian journal of radiation research 0
t. allahverdi pourfallah department of medical physics and biomedical engineering, tehran university of medical sciences, tehran, iran m. allahverdi department of medical physics and biomedical engineering, tehran university of medical sciences, tehran, iran n. riyahi alam department of medical physics and biomedical engineering, tehran university of medical sciences, tehran, iran m.r. ay research center for science and technology in medicine, tehran university of medical sciences, tehran, iran m.h. zahmatkesh novin medical radiation institute, tehran, iran

background: polymer gel dosimetry is still the only dosimetry method for direct measuring of threedimensional dose distributions. mri polymer gel dosimeters are tissue equivalent and can act as a phantom material. in this study the obtained isodose maps with pagat polymer gel dosimeter were compared to those calculated with egsnrs for singleshot irradiations of 8 and 18 mm collimators of gamma ...

M. Allahverdi, M.H. Zahmatkesh, M.R. Ay, N. Riyahi Alam, T. Allahverdi Pourfallah,

Background: Polymer gel dosimetry is still the only dosimetry method for direct measuring of threedimensional dose distributions. MRI Polymer gel dosimeters are tissue equivalent and can act as a phantom material. In this study the obtained isodose maps with PAGAT polymer gel dosimeter were compared to those calculated with EGSnrs for singleshot irradiations of 8 and 18 mm collimators of...

Journal: :iranian journal of radiation research 0
k. adinehvand borujerd islamic azad university, borujerd, iran m.h. zahmatkesh novin radiation medicine institute, tehran, iran m.r aghamiri division of radiation medicine, shahid beheshti university, tehran, iran sh. akhlaghpour department of radiology, tehran university of medical sciences, tehran, iran s. bagheri novin radiation medicine institute, tehran, iran

background: the purpose of this study was to evaluate the dependency of magica polymer gel dosimeter response (r2) on different electron energies as well as on different mean dose rate for a standard clinically used linear accelerator. materials and methods: the sensitivity of the dosimeter was represented by the slope of calibration curve in the linear region measured for each modality. a cali...

2008
Yves De Deene

The use of polymer gels to record radiation dose distributions in three dimensions was first proposed in 1992 as a proof-of-principle [1]. The accuracy of these early polymer gel dosimeters and scanning methods was not sufficient for most clinical applications [2]. Since then, several efforts were made to increase the accuracy and precision of both the physical gel dosimeter and the scanning te...

A.R. Farajollahi, F. Pak, M. Horsfield, Z. Myabi,

Background: In this study the basic radiation properties of N-isopropylacrylamaide polymer gel dosimeter were determined together with verification of its soft tissue equivalency. Materials and Methods: The NIPAM gel was prepared and irradiated approximately 2 h after manufacturing. The magnetic resonance (MR) images were made 24 h after irradiation. The nuclear magnetic resonance (NMR) respons...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید