نتایج جستجو برای: ptfe

تعداد نتایج: 2027  

Journal: :Journal of biomaterials science. Polymer edition 2003
Meng Chen Paul O Zamora Prantika Som Louis A Peña Shigemasa Osaki

The plasma generated from a gas mixture of NH3 plus O2 (NH3 + O2) has been used to impart unique chemical and biological characteristics to polytetrafluoroethylene (PTFE). PTFE treated with NH3 + O2 plasma was physiochemically distinct from surfaces treated with plasma of either NH3 or O2 alone, as determined by electron spectroscopy for chemical analysis (ESCA). The contact angle analysis reve...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه تبریز - دانشکده شیمی 1393

در این کار پژوهشی، پوشش های نیکل- تنگستن (ni-w)، نیکل- تنگستن- پلی کلروتری-فلوئورواتیلن (ni-w-pctfe)، نیکل- تنگستن- پلی تترا فلوئورواتیلن (ni-w-ptfe)، نیکل- تنگستن- فسفر(ni-w-p)، نیکل- تنگستن- فسفر- پلی کلروتری فلوئورواتیلن (ni-w-p-pctfe) ، نیکل- تنگستن- فسفر- پلی تترا فلوئورواتیلن(ni-w-p-ptfe)، نیکل- مولیبدن (ni-mo)، نیکل- مولیبدن- پلی تترا فلوئورواتیلن(ni-mo-ptfe)، نیکل- مولیبدن- فسفر(ni-mo-p...

2016
Hirokazu KATAYAMA Fumihiro HAYASHI Naoki SHIMBARA Atsushi UNO Yoshimasa SUZUKI

Sumitomo Electric Industries, Ltd. invented a technique to make polytetrafluoroethylene (PTFE) porous using PTFE stretching technology, which was patented in 1962.(1) Drawing on the technique, the company has subsequently released various porous PTFE products such as filters and hollow fiber products under the trade name of POREFLON. Porous PTFE filters, one of these porous PTFE products, use s...

2017
Chumpon Wilasrusmee Boonying Siribumrungwong Suthas Horsirimanont Napaphat Poprom Jakrapan Jirasiritham Ammarin Thakkinstian

BACKGROUND Biologic prosthesis (BP) has been reported as a safe alternative to polytetrafluoroethylene (PTFE) in vascular reconstruction. However, efficacy of BP remains controversial. We, therefore, conducted a systematic review to summarize previous available evidences comparing the BP and PTFE in terms of clinical outcomes. MATERIALS AND METHODS A literature search of the MEDLINE and Scopu...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه تبریز - دانشکده شیمی 1388

در کار پژوهشی حاضر فرآیند پراکسی کوآگولاسیون برای رنگزدائی ماده رنگزای زرد بازی 2 از محلولهای آبی با استفاده از الکترودهای کربن- پلی تترافلوئورواتیلن (c-ptfe) و نانولوله های کربن - پلی تترافلوئورواتیلن (cnt-ptfe) بعنوان کاتد بکار برده شد. در ابتدا، جهت ساخت الکترودهای c-ptfe و cnt-ptfe، ترکیبی از نانولوله های کربن با قطر خارجی nm15-8 یا کربن فعال، پلی تترافلوئورواتیلن، آب مقطر و بوتانول تهیه و...

2013
Yanyan Yao Kentaro Yamauchi Goro Yamauchi Tsuyoshi Ochiai Taketoshi Murakami Yoshinobu Kubota

Addition of TiO2 to a polytetrafluoroethylene (PTFE) particle-dispersed composite contributes to the self-cleaning properties of the water-repellent composite. However, its application is limited to outdoor usage or under ultraviolet (UV) irradiation. In this study, a novel visible-light-sensitive photocatalytic and superhydrophobic material was developed by adding Cu/WO3 to a PTFE particulate ...

Journal: :Chemical communications 2015
Amit K Roy Jolien Dendooven Davy Deduytsche Kilian Devloo-Casier Kim Ragaert Ludwig Cardon Christophe Detavernier

This communication reports an approach based on plasma-enhanced atomic layer deposition of aluminium oxide for the functionalization of polytetrafluoroethylene (PTFE or "Teflon") surfaces. Alternating exposure of PTFE to oxygen plasma and trimethylaluminium causes a permanent hydrophilic effect, and a more than 10-fold improvement of the "glueability" of PTFE to aluminium.

2011
Modesto J. Colon Dana A. Telem Edward Chin Kaare Weber Celia M. Divino Scott Q. Nguyen

INTRODUCTION Both polyester composite (POC) and polytetrafluoroethylene (PTFE) mesh are commonly used for laparoscopic ventral hernia repair. However, sparse information exists comparing perioperative and long-term outcome by mesh repair. METHODS A prospective database was utilized to identify 116 consecutive patients who underwent laparoscopic ventral hernia repair at The Mount Sinai Hospit...

2010
Catherine Lussenhop

The XENON100 experiment uses 161kg of liquid xenon divided in two concentric cylinders. The inner volume is the time-projection chamber, the outer volume is the veto, and they are separated by PTFE (Teflon) panels. In the region 350nm to 1200nm, PTFE has a measured reflectivity of 99%. However, xenon emits in the UV region, and the reflectivity distribution is not sufficiently understood here. ...

2000
Duncan M. Price Mark Jarratt

The thermal conductivity of polytetrafluoroethylene (PTFE) was studied using an instrumented thermal conductivity apparatus (Lees Disk) and by DSC. The former method was used to study the effect of incorporating fillers into a PTFE/glass fiber fabric used for conveyor belts in food processing. The effect of crystallinity on thermal conductivity was investigated and different methods of crystall...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید