نتایج جستجو برای: pv

تعداد نتایج: 23706  

Journal: :Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology 2009
Yoav Michowitz Aharon Glick Bernard Belhassen

We present a 34-year-old patient with recurrent episodes of drug refractory paroxysmal atrial fibrillation referred for pulmonary vein (PV) isolation at our institution. During isolation of the right superior PV, a dissociated escape rhythm was observed on a portion of the PV that was disconnected, while the rest of the PV showed clear left atrium to PV conduction. This report demonstrates the ...

2017
K. Burhanudin A. A. A. Samat S. S. Ramli

Power-Voltage (P-V) curve and Current-Voltage (I-V) curve determine the performance of the PV system. In this work, the arrangements of the PV module were reconstructed by adding the number of PV module in 3 strings configuration from 5 to 45. This method enhance the performance of the PV system as it able to show the characteristic of the P-V and I-V curve during partial shading and maximum ir...

Journal: :The Journal of neuroscience : the official journal of the Society for Neuroscience 2004
Lauren M Billings John F Marshall

The globus pallidus (GP) consists of two neuron populations, distinguished according to their immunoreactivity for parvalbumin (PV). The PV-immunoreactive (PV+) neurons project preferentially to "downstream" targets such as the subthalamic and entopeduncular nuclei, whereas neurons lacking PV (PV- neurons) project preferentially to the striatum, suggesting a role for PV- cells in feedback to st...

Journal: :Journal of cardiovascular electrophysiology 2002
Hakan Oral Bradley P Knight Hiroshi Tada Fred Morady

During segmental isolation of the pulmonary veins (PVs) in a patient with paroxysmal atrial fibrillation, there was a PV bradycardia that was dissociated from the left atrium in a segment of the right superior PV, whereas the remaining segments showed passive activation of a PV fascicle during sinus rhythm. Rapid atrial pacing induced a PV tachycardia in the nonisolated fascicles, and the disso...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه سیستان و بلوچستان - دانشکده مهندسی 1389

در این رساله، بهینه سازی چند تابع هدف یک گردآورنده فتوولتائیک حرارتی (pv/t) خورشیدی انجام شده است. بدین منظور، یک تحلیل انرژی و اکسرژی مفصل برای محاسبه پارامترهای حرارتی و الکتریکی، راندمان انرژی کلی، مولفه های اکسرژی و راندمان اکسرژی یک گردآورنده pv/t نمونه انجام شده است. پارامترهای حرارتی و الکتریکی گردآورنده pv/t شامل دمای سلول خورشیدی، دمای سطح زیرین تدلار، دمای سیال خروجی، ولتاژ مدار باز، ...

Journal: :Circulation 2003
Akira Hamabe Yuji Okuyama Yasushi Miyauchi Shengmei Zhou Hui-Nam Pak Hrayr S Karagueuzian Michael C Fishbein Peng-Sheng Chen

BACKGROUND The roles of complex muscle sleeve geometry and fiber orientation in the pulmonary veins (PVs) in wave-front propagation are poorly understood. METHODS AND RESULTS We mapped the left superior PV (LSPV, n=7) and left inferior PV (LIPV, n=4) of dogs with 420 bipolar electrodes (1-mm resolution) and performed detailed histological examination. In the anterior LSPV-left atrial (LA) jun...

Journal: :Circulation. Arrhythmia and electrophysiology 2013
Jim W Cheung Frank S Lin James E Ip Seth R Bender Faisal K Siddiqi Christopher F Liu George Thomas Steven M Markowitz Bruce B Lerman

BACKGROUND Adenosine can unmask dormant pulmonary vein (PV) conduction after PV isolation. Adenosine can also induce ectopy in electrically silent PVs after isolation, possibly via activation of autonomic triggers. We sought to identify the implications of adenosine-induced PV ectopy for atrial fibrillation (AF) recurrence after PV isolation. METHODS AND RESULTS A total of 152 patients (age, ...

2009
H. I. Cho S. M. Yeo C. H. Kim V. Terzija Z. M. Radojević

-This paper presents a steady-state model of a gridconnected photovoltaic (PV) system using Electromagnetic Transient Program (EMTP) MODELS. Recently the PV system has been introduced in power systems. The previous PV generation was used only to supply small loads or for home use. Nowadays, installations of grid-connected PV systems are increasing due to several advantages compared to standalon...

2015
Jinsung Park Dong-Gi Lee Beomseok Suh Sung Yong Cho In Ho Chang Sung Hyun Paick Hyung-Lae Lee

We aimed to determine normal reference ranges for prostate volume (PV) and annual PV change rate in a Korean nationwide screening population. Data from men who underwent a routine health check-up were collected from 13 university hospitals. The cohort comprised men aged ≥40 yr who had undergone 2 or more serial transrectal ultrasonographies. Men with initial PV>100 mL; serum PSA level>10 ng/mL;...

2011
Ben Hoen Ryan Wiser Peter Cappers Mark Thayer

The market for photovoltaic (PV) energy systems is expanding rapidly in the U.S. Almost 100,000 PV systems have been installed in California alone, more than 90% of which are residential. Some of those “PV homes” have sold, yet little research exists estimating if those homes sold for significantly more than similar non-PV homes. A clearer understanding of these effects might influence the deci...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید