نتایج جستجو برای: radius fractures

تعداد نتایج: 104302  

 Background:It is possible that some hamate hook fractures are not diagnosed or treated, thereby affecting the study of their natural history. Study of the prevalence of incidental hamate hook fractures, nonunions, and other abnormalities on computed tomography (CT) ordered for another reason could document a subset of undiagnosed and untreated hamate hook fractures which might change our under...

F Eslamiyan J Ganjpour J Soleimanpour M GHorbanzadeh

Background & Aims: Metaphysical distal radius fractures are common fractures account for almost half of the fractures in Orthopaedic Emergencies. According to different studies, 1-6 weeks cast immobilization after distal radius surgery has been recommended. The aim of this study was to compare outcomes and complications of short-term and long-term immobilization treatment methods. Methods: In a...

Journal: :archives of trauma research 0
kavin khatri department of orthopaedics, ggs medical college faridkot, baba farid university of health sciences, faridkot, india; department of orthopaedics, ggs medical college faridkot, baba farid university of health sciences, faridkot, india. tel: +91-8743878077 vijay sharma department of orthopaedics, jai prakash narayan apex trauma centre, all india institute of medical sciences, (aiims), new delhi, delhi, india kamran farooque department of orthopaedics, jai prakash narayan apex trauma centre, all india institute of medical sciences, (aiims), new delhi, delhi, india vivek tiwari department of orthopaedics, jai prakash narayan apex trauma centre, all india institute of medical sciences, (aiims), new delhi, delhi, india

conclusions the use of variable-angle locking plates in treating unstable distal end radius fractures is associated with excellent to good functional outcomes with minimal complications. objectives this study aimed to evaluate the functional and radiological outcomes in unstable distal end radius fractures treated with variable-angle locking plates. patients and methods we reviewed 23 unstable ...

Journal: :Journal of Medical Case Reports 2008
Korhan Ozkan Ender Ugutmen Koray Unay Oğuz Poyanli Melih Guven Abdullah Eren

INTRODUCTION Bilateral fractures of the distal radius and scaphoid are extremely rare injuries. CASE PRESENTATION A patient with bilateral comminuted, displaced distal fractures of the radius and bilateral fractures of the scaphoid was treated via internal fixation of the scaphoid fractures with Herbert screws and internal fixation of the distal radius fractures with locked volar plating. C...

Background: To examine whether interobserver reliability, decision-making, and confidence in decision-making in thetreatment of distal radius fractures changes if radiographs are viewed on a messenger application on a mobile phonecompared to a standard DICOM viewer.Methods: Radiographs of distal radius fractures were presented to surgeons on either a smart phone using a mobilemessenger applicat...

2013
Scott W. Wolfe

With the wide array of treatment options now available, this is an exciting era for the treatment of fractures of the distal radius. An improved understanding of kinematics, bone quality, and muscle forces acting across the fracture has led to increased awareness of a fracture’s relative stability, as well as the development of innovative devices to counteract these forces and restore stability...

Journal: :Journal of orthopaedic trauma 2009
Frank A Liporace Mark R Adams John T Capo Kenneth J Koval

Distal radius fractures are a common injury, particularly in the elderly population. Severity of these fractures is directly related to the bone mineral density of the patient, and clinical results are dependent on this parameter as well. In terms of treatment, several options exist. Nonoperative management consists of closed treatment with casting. Operative treatment options include intrafoca...

2016
Mats Wadsten Göran Sjödén Arkan Sayed-Noor

Till familjen " I hear and I forget. I see and I remember. I do and I understand. " Confucius (551BC-479BC) Abstract iii List of publications vi List of abbreviations vii Definitions viii Sammanfattning (summary in Swedish) ix Introduction 1

2017
Hari Krishna Reddy

Introduction: The most common cause of distal radius fracture is a fall on an outstretched hand. Osteoporosis can make a relatively trivial fall result in a broken wrist. Many distal radius fractures in people older than 60 years of age are caused by a fall from a standing position Methodology: Total of 1336 bony injuries were reported to Hospital casualty and orthopedic opd during the study pe...

2017
Z Gamie R Sehjal K Lowery D L Shaw

Simultaneous ipsilateral distal and proximal fractures of the forearm are rare [1-3]. There have been case reports describing an olecranon fracture associated with an ipsilateral distal radius epiphyseal injury[1], a Monteggia lesion with an associated ipsilateral distal radius epiphyseal injury[4] or associated with ipsilateral distal radius and ulna metaphyseal fractures[5, 6]. Furthermore, t...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید