نتایج جستجو برای: recirculation time

تعداد نتایج: 1894497  

Journal: :Bioresource technology 2008
A Suna Erses Turgut T Onay Orhan Yenigun

Two landfill bioreactors were operated under aerobic and anaerobic conditions in a thermo-insulated room at a constant temperature of 32 degrees C. Reactors were filled with 19.5 kg of shredded synthetic solid waste prepared according to the average municipal solid waste compositions determined in Istanbul and operated under wet-tomb management strategy by using leachate recirculation. Aerobic ...

Journal: :Biotechnology and bioengineering 2003
Vasily A Vavilin Sergey V Rytov Ljudmila Ya Lokshina Spyros G Pavlostathis Morton A Barlaz

A distributed model of solid waste digestion in a 1-D bioreactor with leachate recirculation and pH adjustment was developed to analyze the balance between the rates of polymer hydrolysis/acidogenesis and methanogenesis during the anaerobic digestion of municipal solid waste (MSW). The model was calibrated on previously published experimental data generated in 2-L reactors filled with shredded ...

Journal: :international journal of environmental research 0
m. moroni department of civil and environmental engineering, sapienza university of rome, via eudossiana, 18 – 00184, rome, italy f. la marca department of chemical engineering materials & environment, sapienza university of rome, via eudossiana, 18 – 00184, rome, italy l. cherubini department of chemical engineering materials & environment, sapienza university of rome, via eudossiana, 18 – 00184, rome, italy a. cenedese department of civil and environmental engineering, sapienza university of rome, via eudossiana, 18 – 00184, rome, italy

plastic recycling is the process of recovering scrap or waste plastics and reprocessing thematerial into useful products that sometimes differ completely in form from their original state. an importantissue in plastic recovery and recycling is that plastic waste usually contains a variety of plastics that differ intheir physical and chemical properties. separation of recovered plastics into dis...

لسان پزشکی, محبوب, کردی, آرش, غلیاف , محمود ,

Hemodialysis access recirculation occurs when dialyzed blood returning through the venous needle reenters the extracorporeal circuit through the arterial needle rather than returning to the systemic circulation. It is important to meausre hemodialysis access recirculation for two reasons: The reentry of dialyzed blood into the extracorporeal circuite reduces solute  &n...

Journal: :American journal of physiology. Gastrointestinal and liver physiology 2013
Yohsuke Imai Ikuma Kobayashi Shunichi Ishida Takuji Ishikawa Martin Buist Takami Yamaguchi

We investigate flow in the stomach during gastric mixing using a numerical simulation with an anatomically realistic geometry and free-surface flow modeling. Because of momentum differences between greater and lesser curvatures during peristaltic contractions, time-averaged recirculation is generated in the antrum, with retropulsive flow away from the pylorus and compensation flow along the gre...

2018
Claire Delsuc Alexandre Faure Julien Berthiller Didier Dorez Xavier Matillon Vannary Meas-Yedid Bernard Floccard Guillaume Marcotte Vanessa Labeye Maud Rabeyrin Ricardo Codas Cécile Chauvet Philip Robinson Emmanuel Morelon Lionel Badet William Hanf Thomas Rimmelé

BACKGROUND Kidney transplantation following uncontrolled donation after circulatory death (uDCD) presents a high risk of delayed graft function due to prolonged warm ischemia time. In order to minimise the effects of ischemia/reperfusion injury during warm ischemia, normothermic recirculation recently replaced in situ perfusion prior to implantation in several institutions. The aim of this stud...

1997
ZHENGYU LIU

A two-layer quasigeostrophic model is used to investigate the influence of stratification on the inertial recirculation in a full basin model. It is found that the barotropic transport of the inertial recirculation is intensified significantly through barotropic–baroclinic interactions in the presence of a shallow thermocline or a strong stratification. Weakly nonlinear theories and numerical e...

Journal: :The journal of extra-corporeal technology 2008
David Clements Johanna Primmer Pamela Ryman Bonnie Marr Bruce Searles Edward Darling

Recirculation during dual lumen veno-venous (DLVV) extracorporeal membrane oxygenation (ECMO) is a dynamic event that results in a fraction of the oxygenated blood exiting the arterial lumen and immediately shunting back into the venous lumen. Excessive recirculation will result in suboptimal oxygen delivery to the patient. Ultrasound dilution is a technology that has been shown to rapidly quan...

Journal: :فرآوری و نگهداری مواد غذایی 0

spray drying is one of the most important processes applied in the industry. the equipment used in this process evaporates water in a very short time and so, need a lot of energy. in this work, we used microsoft excel as an analysis tool for the optimization of fuel usage in this dryer. we have described the process in terms of thermodynamic calculations and mass and heat balance equations. our...

Journal: :Seminars in nephrology 2005
Andrew J Cortez William D Paulson Steve J Schwab

Vascular accesses consist of permanent arteriovenous (AV) accesses (autogenous fistulas and synthetic grafts) and venous accesses (central venous catheters [CVCs]). AV accesses have fewer complications than venous accesses, and are therefore the preferred hemodialysis access. An important additional issue is whether the type of access influences adequacy of dialysis (i.e. Kt/V). Key limiting fa...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید