نتایج جستجو برای: relaxometry

تعداد نتایج: 838  

2018
Enrico Tedeschi Sirio Cocozza Pasquale Borrelli Lorenzo Ugga Vincenzo Brescia Morra Giuseppe Palma

We report the assessment of Dentate Nuclei (DN) R1 (1/T1) and R2* (1/T2*) values in a patient with relapsing-remitting Multiple Sclerosis, exposed to 22 standard (0.1 mmol/kg) doses of gadobutrol, who underwent eight relaxometric MR measurements within 2 years. DN R1 did not significantly increase nor correlated with cumulative gadobutrol administration, even after a total dose of 130 ml. Likew...

Journal: :iranian journal of radiology 0
li liu department of radiology, shanghai cancer center, fudan university, shanghai, china bo yin department of radiology, huashan hospital, fudan university, shanghai, china dao ying geng department of radiology, huashan hospital, fudan university, shanghai, china yi ping lu department of radiology, huashan hospital, fudan university, shanghai, china wei jun peng department of radiology, shanghai cancer center, fudan university, shanghai, china; department of radiology, shanghai cancer center, fudan university, shanghai, china. tel: +86-13817515007

conclusion in breast cancer after nac, the lesion t2 relaxation time was reduced in the responders, and this finding is potentially useful to assess the response to nac. results in 26 cases with nac, the mean lesion t2 relaxation time before nac was 81.34 ± 13.68 ms, compared with 64.50 ± 8.71 ms after nac. significant differences in the lesion t2 relaxation times existed between the pre- and p...

2016
David P. Cistola Michelle D. Robinson

Nuclear magnetic resonance relaxometry is a uniquely practical and versatile implementation of NMR technology. Because it does not depend on chemical shift resolution, it can be performed using low-field compact instruments deployed in atypical settings. Early relaxometry studies of human blood were focused on developing a diagnostic test for cancer. Those efforts were misplaced, as the measure...

Journal: :The Journal of chemical physics 2004
Peter A Beckmann Carol Paty Elizabeth Allocco Maria Herd Carolyn Kuranz Arnold L Rheingold

We report x-ray diffractometry in a single crystal of 2-t-butyl-4-methylphenol (TMP) and low-frequency solid state nuclear magnetic resonance (NMR) proton relaxometry in a polycrystalline sample of TMP. The x-ray data show TMP to have a monoclinic, P2(1)/c, structure with eight molecules per unit cell and two crystallographically inequivalent t-butyl group (C(CH(3))(3)) sites. The proton spin-l...

2014
Ulrike Löbel Ferdinand Schweser Miriam Nickel Andreas Deistung Regine Grosse Christian Hagel Jens Fiehler Angela Schulz Monika Hartig Jürgen R Reichenbach Alfried Kohlschütter Jan Sedlacik

Therapeutic trials for Neurodegeneration with Brain Iron Accumulation have aimed at a reduction of cerebral iron content. A 13-year-old girl with mitochondrial membrane protein-associated neurodegeneration treated with an iron-chelating agent was monitored by R2 relaxometry, R2* relaxometry, and quantitative susceptibility mapping to estimate the brain iron content. The highly increased brain i...

2016
Christian R. Hamilton-Craig Mark W. Strudwick Graham J. Galloway

Cardiac magnetic resonance (CMR) imaging has been widely used to assess myocardial perfusion and scar and is the non-invasive gold standard for identification of focal myocardial fibrosis. However, the late gadolinium enhancement technique is limited in its accuracy for absolute quantification and assessment of diffuse myocardial fibrosis by technical and pathophysiological features. CMR relaxo...

بختیاری, مرتضی, حمیدی ابرقویی, زهره, ریاحی عالم, نادر, سرکار, سعید , شاکری, ناصر, عقابیان, محمدعلی, قاسم زاده, علی, قناعتی, حسین, لاریجانی, باقر,

Introduction & Objective : The aim of this study was to optimize MRI conventional protocols for BMD(Bone Mineral Density) measurements using MRI Relaxometry in systems not facilitated with special multi echo protocols. Since, cortical and trabecular bone separation can not be performed in DEXA, so the results might lead to erroneous interpretation of BMD values. One method for bone quality dete...

2015
David Milford Nicolas Rosbach Martin Bendszus Sabine Heiland Xiaobing Fan

INTRODUCTION T2 relaxometry has become an important tool in quantitative MRI. Little focus has been put on the effect of the refocusing flip angle upon the offset parameter, which was introduced to account for a signal floor due to noise or to long T2 components. The aim of this study was to show that B1 imperfections contribute significantly to the offset. We further introduce a simple method ...

Journal: : 2023

The possibility of fixing velocities fluid motion in model porous medium (glass beads) by measuring the transverse relaxation time T 2 spin echo method is shown. magnetic field gradient arising due to difference permeability and causes a decrease average , wich makes it possible fix absence an external gradient. addition nanoparticles under study increases dependence on velocity sensitivity det...

Journal: :iranian journal of medical physics 0
reza moghadam-drodkhani m.sc. in medical physics, medical physics and engineering dept., faculty of medicine, tehran university of medical sciences, tehran, iran nader riyahi-alam professor, medical physics and engineering dept., faculty of medicine, tehran university of medical sciences, tehran, iran abbas takavar professor, medical physics and engineering dept., faculty of medicine, tehran university of medical sciences, tehran, iran kavous firoznia associate professor, radiology dept., imaging center of imam khomeini hospital, faculty of medicine, tehran university of medical sciences, tehran, iran peiman hadad associate professor, radiotherapy dept., imam khomeini hospital, faculty of medicine, tehran university of medical sciences, tehran, iran behrooz rafiee m.sc., radiology dept., imaging center of imam khomeini hospital, faculty of medicine, tehran university of medical sciences, tehran, iran

introduction: the conventional methods of dosimetry are not capable of dosimetry in such a small volume of less than one cubic millimeter. although the polymer gel dosimetry method based on magnetic resonance imaging (mri) could achieve three dimensional dosimetry with high resolution, a spatial resolution evaluation based on gel dose modulation transfer function has not been investigated yet. ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید