نتایج جستجو برای: sao2
تعداد نتایج: 823 فیلتر نتایج به سال:
Six pulse oximeters with finger probes were studied in three groups of 17 hypoxemic patients with COPD aged 50 to 75 years. Transcutaneous arterial oxygen saturation (SpO2) was measured with the Nellcor N101 (oximeter 1a), the Ohmeda Biox III (oximeter lb), the Nellcor N200 (oximeter 2a), the Critikon Oxyshuttle (oximeter 2b), the Radiometer Oxi100 (oximeter 3a), and the Ohmeda Biox 3700 (oxime...
INTRODUCTION Pulse oximetry may overestimate arterial oxyhemoglobin saturation (Sao2) at low Sao2 levels in individuals with darkly pigmented skin, but other factors, such as gender and oximeter probe type, remain less studied. METHODS We studied the relationship between skin pigment and oximeter accuracy in 36 subjects (19 males, 17 females) of a range of skin tones. Clip-on type sensors and...
INTRODUCTION This study investigates the relation between changes in pulse oximeter oxygen saturation (SpO2) and changes in arterial oxygen saturation (SaO2) in the critically ill, and the effects of acidosis and anaemia on precision of using pulse oximetry to predict SaO2. PATIENTS AND METHODS Forty-one consecutive patients were recruited from a nine-bed general intensive care unit into a 2-...
Background and Objective: In order to determine the Hypoxemia and prognosis of patients with covid-19 hospitalized in the intensive care unit, reliable oxygen supply indicators are needed. In this situation, the examination of the percentage of arterial oxygen saturation (SaO2) and arterial oxygen pressure (PaO2), as well as their relationship, may be helpful. Materials and Methods: This des...
Pulse oximeters are used to noninvasively measure oxygen saturation in arterial blood (SaO2). Although arterial oxygen saturation measured by pulse oximeter (SpO2) is usually indicated in 1% increments, the value of SaO2 from arterial blood gas analysis is not an integer. We have developed a new pulse oximeter that can measure SpO2 to one digit after the decimal point. The values of SpO2 from t...
To determine the effect of moderate altitude on arterial oxygen saturation (SaO2), pulse oximetry was performed on 302 children aged <3 months attending a clinic in Goroka, Eastern Highlands Province (1584 metres above sea level) for minor ailments or immunization. Respiratory and heart rates were also measured. The overall mean SaO2 was 96%. Comparison between log-transformed means showed that...
Oxygen saturation of arterial blood (SaO2) was assessed in children after discontinuing N2O/O2 sedation for dental procedures. Two post-treatment methods were used: breathing 100% O2 for 5 min after the procedure, and breathing room air for 5 min. Participants were 24 healthy children ages 41 to 113 months. Each child was treated twice and a crossover design was used. The mean length of procedu...
BACKGROUND Recurrent nocturnal hypoxemia in obstructive sleep apnea enhances sympathetic function, decreases baroreceptor sensitivity, and weakens peripheral vascular responses to adrenergic signals. The authors hypothesized that the percentage of total sleep time spent at oxyhemoglobin saturation (SaO2) less than 90% and minimum nocturnal SaO2 on preoperative polysomnography are associated wit...
There is an error in the first three sentences under the subheading “Cut-Off value of SpO2” in the Results section. The correct sentences are: We hypothesized that the cut-off value of each pulse oximeter to detect hypoxemia (SaO2< = 90% or PaO2< = 60 mmHg) was different. We calculated the sensitivity, specificity, PPV, and NPV of each pulse oximeter to detect hypoxemia. As shown in Table 5, th...
Although the behavior and factors of exercise tolerance have been studied during exercise in patients with chronic obstructive pulmonary disease (COPD), little attention has been paid to the after-effects of such activity. Arterial oxygen saturation (SaO2) was monitored during and after a 10 min walking exercise in aged patients with COPD. Neither baseline SaO2 nor mean SaO2 during exercise cor...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید