نتایج جستجو برای: selective membrane electrode

تعداد نتایج: 631334  

Journal: :physical chemistry and electrochemistry 0

a pvc ion-selective membrane electrode based on cd-tetraphenyl porphyrine as a carrier was prepared fordetermination of mno4- ion. this electrode revealed good selectivity toward permanganate ion over a widevariety of anions. effects of some experimental parameters such as nature of the plasticizer, the amounts ofcarrier and additive, and concentration of the internal solution on the potential ...

Journal: :journal of physical & theoretical chemistry 2012
m. h. fekri m. darvishpour

a pvc membrane ni(ii) ion selective electrode has been constructed using (1e,2e)-bis(2-aminophenyl)n'1,n'2-dihydroxyethanebis as membrane carrier. the electrode exhibited a goodpotentiometric response for ni(ii) over a wide concentration range 1.0×10-4 to 1.0×10-1m with aslope of 29.4±0.5 mv/decade a and a working ph range of 6.5-9.0. it had a fast response time of≤20s. the best performance was...

Journal: :journal of physical & theoretical chemistry 2012
r. aminameli m. h. fekri h. shafie m. darvishpour h. khanmohammadi

a pvc membrane fe(iii) ion selective electrode has been constructed using a new macrocyclic asmembrane carrier.the electrode exhibits a good potentiometric response for fe(iii) over a wideconcentration range 1.0×10-4 to 1.0×10-1m with a slope 19.4±0.5 mv/decade a and a working phrange of 6.5-9.0. it has a fast response time ≤30s.the best performance was observed with themembrance having the 30....

Journal: :journal of physical & theoretical chemistry 2004
h. aghaie m. giahi1 giahi m. aghaei m. arvand3

we found that dibenzo-18-crown-6 (db18c6) can be used as an ionophore to make a tin (ii)-ionselectivemembrane electrode. the electrode exhibits a near nernstian response for sn2+ ions over aconcentration range from 1.0× 10-6 – 1.0× 10-2 m with a slope of 27.5 ± 0.6 mv per concentration decadein an acidic solution (ph=1). the limit of detection was 8.0× 10-7 m. it has a response time of < 20s an...

Journal: :journal of physical and theoretical chemistry 0
m. h. fekri - m. darvishpour -

a pvc membrane ni(ii) ion selective electrode has been constructed using (1e,2e)-bis(2-aminophenyl)n&apos;1,n&apos;2-dihydroxyethanebis as membrane carrier. the electrode exhibited a goodpotentiometric response for ni(ii) over a wide concentration range 1.0×10-4 to 1.0×10-1m with aslope of 29.4±0.5 mv/decade a and a working ph range of 6.5-9.0. it had a fast response time of≤20s. the best perfo...

Journal: :journal of physical and theoretical chemistry 0
m. aghaie - m. h. fekri - m. giahi - e. baghdar - s. farhadi -

in order to study the cu(ii) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of pvc powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. the sensor showed a near nernstian response for cu(ii) ions over a concentration range from 1.0×0-6 –1.0×0-2 m with a slope of 28.90.5 mv per concentration decade with a working ph range of 3.5-6.3. ...

Journal: :journal of physical & theoretical chemistry 2004
hossein aghaei masood giahi majjid arvand mehran aghaei

tin(ii)-ion-selective electrode consisting of dibenzo-18-crown-6 (db18c6) as an ionophore inpvc matrix was developed. the influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. the electrodeshowed a near nernstian response for sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 m with a slope of 27...

Journal: :journal of physical & theoretical chemistry 2007
m. aghaie m. h. fekri m. giahi e. baghdar s. farhadi

in order to study the cu(ii) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of pvc powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. the sensor showed a near nernstian response for cu(ii) ions over a concentration range from 1.0×0-6 –1.0×0-2 m with a slope of 28.90.5 mv per concentration decade with a working ph range of 3.5-6.3. ...

Journal: :journal of physical & theoretical chemistry 2007
masoud giahi mohammad ali bagherinia azin azari

sol-gel and polymeric membrane electrodes, based on thiacalix[4]arene as a neutral carrier, weresuccessfully developed for the detection of vo2+ in aqueous solutions. the sol-gel and pvcmembrane electrodes exhibited linear response with nernstian slopes of 29.3 and 28.4 mv perdecade, respectively, within the vanadyl ion concentration ranges from 1.0 × 10-6 to 1.0 × 10-1mol dm-3 and from 1.0 × 1...

Journal: :journal of the iranian chemical research 0
ali benvidi department of chemistry, faculty of science, yazd university, yazd, iran mehdi elahizadeh department of chemistry, faculty of science, yazd university, yazd, iran hamid reza zare, department of chemistry, faculty of science, yazd university, yazd, iran rasoul vafazadeh department of chemistry, faculty of science, yazd university, yazd, iran

an iodide ion-selective pvc membrane sensor based on copper (π)-bis-nphenilsalicyldenaminatocomplex as a novel sensing material is successfully developed. theelectrode showed a good selectivity for iodide ion with respect to common inorganic anions. thesensor exhibited a good linear response with slope of _58.6 ± 0.4 mv per decade over theconcentration range of 5.0 × 10-6 to 1.0 × 10-1 mol l-1,...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید