نتایج جستجو برای: septal occluder device

تعداد نتایج: 705866  

Journal: :Heart 2001
P Acar Z Saliba P Bonhoeffer D Sidi J Kachaner

OBJECTIVE To apply three dimensional echocardiography to describe the geometric profile of the Amplatzer and Cardioseal occluders after deployment for closure of atrial septal defect. METHODS 20 patients (mean (SD) age, 14 (5) years) were enrolled for transcatheter closure of a secundum atrial septal defect with the Amplatzer occluder (10) or with the Cardioseal occluder (10). The two populat...

Journal: :the journal of tehran university heart center 0
mehdi ghaderian emam hosein medical, educational and research center, esfahan university of medical sciences, esfahan, iran and rajaie cardiovascular, medical and research center, iran university of medical sciences, tehran, iran. mahmood merajie rajaie cardiovascular, medical andresearch center, iran university of medical sciences, tehran, iran. hodjjat mortezaeian rajaie cardiovascular, medical andresearch center, iran university of medical sciences, tehran, iran. mohammadyoosef aarabi-moghadam rajaie cardiovascular, medical andresearch center, iran university of medical sciences, tehran, iran.

background: the ductus arteriosus connects the main pulmonary trunk to the descending aorta. the incidence of isolated patent ductus arteriosus (pda) in full-term infants is about 1 in 2000. the amplatzer ductal occluder (ado) is recommended for pdas with sizes larger than 2 mm. in this procedure, we must confirm the ado position in pda by aortogram from the arterial line. the purpose of this s...

2012
Fatemeh Nabavizadeh Navin C Nanda Amitoj Singh Carmen Mateescu

Six female patients aged from 19 to 73 years, with ostium secundum atrial septal defect underwent closure procedure with Amplatzer septal occluder device. Three-dimensional Echocardiography (3D-TEE) was done during the procedure or one day after the procedure. 3D-TEE provides incremental value over Two- dimensional trans-esophageal echocardiography in measuring Amplatzer septal occluder disc si...

Journal: :JACC. Cardiovascular interventions 2015
Daxin Zhou Wenzhi Pan Lihua Guan Cuizhen Pan Junbo Ge

(A) Before the procedure, large residual ventricular septal shunts could be seen between the occluder and the peak of apex (Online Video 1). (B) After the procedure, the shunts decreased significantly (Online Video 2). LV 1⁄4 left ventricle; RV 1⁄4 right ventricle. A 58-year-old man with exertional dyspnea (New York Heart Association class II) was admitted to our hospital. He suffered from acut...

2012
Gokhan Gokaslan Hasim Ustunsoy Hayati Deniz Ozerdem Ozcaliskan Alptekin Yasim Osman Baspinar Gokalp Guzel

BACKGROUND In this study, we sought to analyze our experience in urgent surgical management for embolized cardiac septal and ductal occluder devices resulting from trans-catheter closure of atrial septal defect, ventricular septal defect and patent ductus arteriosus in childhood patient group. METHODS We retrospectively reviewed 9 patients (aged 2-15 years) who underwent urgent surgery due to...

2017
Li-Jian Zhao Bo Han Jian-Jun Zhang Ying-Chun Yi Dian-Dong Jiang Jian-Li Lyu Chun-Yan Guo

Transcatheter device closure was performed under general anesthesia in all the patients. The interventional treatment modality was approved by the ethics committee of our hospital, and informed consent was obtained before the procedure. Femoral artery and vein was routinely punctured. Left ventricular angiography was performed at 60° left anterior oblique and 20° cranial tilt position. The entr...

Journal: :the journal of tehran university heart center 0
mostafa behjati-ardakani yazd cardiovascular research center, shahid sadoughi university of medical sciences, yazd, iran. mohammadamin behjati-ardakani baqiyatallah university of medical sciences, tehran, iran. mohammadhassan abdollahi yazd cardiovascular research center, shahid sadoughi university of medical sciences, yazd, iran.

background: t ranscatheter closure of patent ductus arteriosus (pda) has become an alternative treatment to surgery. we evaluated the long-term results of the transcatheter closure of pda with the amplatzer duct occluder (ado) in children. methods: between may 2004 and october 2012, 138 children with pda (43 males and 95 females) underwent transcatheter pda closure. clinical, electrocardiograph...

Journal: :Turk Kardiyoloji Dernegi arsivi : Turk Kardiyoloji Derneginin yayin organidir 2015
Oktay Ergene Nihan Kahya Eren Cem Nazlı Hamza Duygu Uğur Kocabaş

OBJECTIVE Percutaneous closure of perimembranous ventricular septal defects (pmVSD) has become an accepted alternative to surgical closure in selected cases. However, closure of pmVSDs associated with septal aneurysm is more challenging. We report our experience of device closure of pmVSDs associated with septal aneurysm. METHODS Between 2008 and 2012, percutaneous closure of pmVSD associated...

2014
Kevin Belgrave Shaun Cardozo

The use of interatrial septal occluder devices is an efficacious and less invasive alternative to open heart surgery for the repair of atrial septal defects. These devices present significant risks including thrombus formation on the device and subsequent thromboembolic events. We present a case of a woman who presented with stroke-like symptoms five years after PFO closure. The patient was sub...

2002
Daniel R. Turner Carl Y. Owada Charlie J. Sang Muhammad Khan D. Scott Lim

BACKGROUND Prospective data on the medium-term safety and effectiveness of the AMPLATZER Septal Occluder in clinical practice are not available. The objective of this study was to prospectively evaluate the risk of hemodynamic compromise and obtain medium-term survival data on patients implanted with the AMPLATZER Septal Occluder for percutaneous closure of secundum atrial septal defects. MET...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید