نتایج جستجو برای: siemens primus linac
تعداد نتایج: 9554 فیلتر نتایج به سال:
the monte carlo method can be used to describe any technique that approximates solutions to quantitative problems through statistical sampling. this method is considered to be the most accurate method for dose calculation in radiotherapy. for complete modeling of a linear accelerator, it is required that the manufactured information covers all data, but some data such as primary electron energy...
Background: Neutron contamination is produced in electron beams of linac when tooth or dental materials are located in the path of beam. Objective: This study aims to determine the neutron dose contamination from different dental restoration materials in electron mode of a linac. Material and Methods: In this experimental study, the neutron dose contamination was calculated in the p...
The Percentage Depth Dose (PDD) and dose profile of X-Ray output from a LINAC therapy device have been modeled analyzed. research was conducted by simulation method through the use Particle Heavy Ion Transport code System (PHITS) program. in this work refers to Siemens Primus device, which is operated at 6 MV, 10 MV 18 voltages. Determination PDD carried depth 0-30 cm 0-20 water phantom, placed...
Several investigators have pointed out that electron and neutron contamination from high-energy photon beams are clinically important. The aim of this study is to assess electron and neutron contamination production by various prostheses in a high-energy photon beam of a medical linac. A 15 MV Siemens PRIMUS linac was simulated by MCNPX Monte Carlo (MC) code and the results of percentage depth ...
PURPOSE To develop an ultrasound-based source to skin surface distance (SSD) measurement technique and device for patient setup and test its feasibility and accuracy. METHODS AND MATERIALS The ultrasonic SSD measurement device (USD) prototype consists of two main parts: a probe plate with an ultrasonic transducer in the center and a control unit that displays the SSD in millimeters. The probe...
background: ebt and ebt3 radiochromic films have been used in radiotherapy dosimetry for years. objective: the aim of the current study is to compare ebt and ebt3 radiochromic films in dosimetry of radiotherapy fields for treatment of parotid cancer. methods: calibrations of ebt and ebt3 films were performed with identical setups using a 6 mv photon beam of a siemens primus linac. skin dose was...
objective: radiochromic ebt3 film is a later generation of radiochromic films. the aim of this study is to compare ebt and ebt3 radiochromic films in radiotherapy fields of breast cancer. methods: a rando phantom was irradiated by a 6 mv siemens primus linac with medial and lateral fields of radiotherapy of breast cancer. dosimetry was performed in various points in the fields using ebt and ebt...
Introduction: Monte Carlo calculation method is considered to be the most accurate method for dose calculation in radiotherapy. The purpose of this research is comparison between 6 MV Primus LINAC simulation output with commissioning data using EGSnrc and build a Monte Carlo geometry of 6 MV Primus LINAC as realistically as possible. The BEAMnrc and DOSXYZnrc (EGSnrc package) M...
background: in order to deliver the precise dose to the target in radiotherapy, absorbed dose to water at the reference point should be assessed. when the calibration procedure is performed for a reference dosimeter in the 60co beam of a secondary standard dosimetry laboratory (ssdl), the total uncertainty in absorbed dose to water (dw) is estimated to be approximately 1.5%. this study attempts...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید