نتایج جستجو برای: stapes teflon piston

تعداد نتایج: 7026  

Journal: :Brazilian journal of otorhinolaryngology 2013
Andre Luiz de Ataide Gerson Linck Bichinho Tatiana Mauad Patruni

UNLABELLED Otosclerosis causes the fixation of the stapes and conductive hearing loss, usually corrected with the use of hearing aids or through stapedotomy and the replacement of the involved stapes with a prosthesis. Titanium has been the most recently used material of choice in stapedotomy prostheses. Only two prostheses are commercially available in Brazil. There are no reports in the liter...

Journal: :AJNR. American journal of neuroradiology 2014
J Whetstone A Nguyen A Nguyen-Huynh B E Hamilton

BACKGROUND AND PURPOSE Prior descriptions of imaging after failed stapes procedures for otosclerosis predated currently available CT technology and/or failed to assess commonly used metallic implants. The purpose of this study was to correlate temporal bone CT findings with clinically and intraoperatively determined causes of surgical failure. MATERIALS AND METHODS All patients with otosclero...

Journal: :The Laryngoscope 2014
Jeremy Lavy Sherif Khalil

OBJECTIVES/HYPOTHESIS To evaluate the long-term (5-year) results of the shape-memory nitinol stapes piston in the surgical treatment of otosclerosis. STUDY DESIGN Retrospective case review in a tertiary referral center. METHODS The patients were adults with clinically proven otosclerosis undergoing stapedotomy. Stapedotomy and ossicular chain reconstruction using a shape-memory nitinol stap...

2017
Monika Kwacz Magdalena Sołyga Maciej Mrówka Konrad Kamieniecki

Piston-stapedotomy is the most common method for hearing restoration in patients with otosclerosis. In this study, we have experimentally examined a prototype of a new chamber stapes prosthesis. The prototype was implanted in a human cadaver temporal bone. The round window vibrations before and after implantation were measured for the acoustic signal (90 dB SPL, 0.8-8 kHz) in the external audit...

Journal: :Journal of the Chinese Medical Association : JCMA 2010
Chin-Lung Kuo Mao-Che Wang An-Suey Shiao

BACKGROUND A growing number of studies conducted on stapes surgery have suggested that firm and adequate attachment of the prosthesis onto the long process of the incus plays a key role in surgical success. For this reason, a new prosthesis made of Nitinol characterized by "self-crimping" has been developed. Although better postoperative outcomes achieved with a Nitinol piston have been previou...

2016
Charlotte M. Chiong

Results: Audiometric evaluation showed a maximal unilateral left conductive hearing loss. High resolution temporal bone CT showed absence of the oval window on the left along with facial and stapes abnormalities. Exploratory tympanotomy showed an aberrant facial nerve, monopodal and abnormally located stapes and absent oval window. Postoperative hearing gain achieved after a neo-oval window and...

2015
Martin Grossöhmichen Rolf Salcher Hans-Heinrich Kreipe Thomas Lenarz Hannes Maier

This work assesses the efficiency of the Codacs system actuator (Cochlear Ltd., Sydney Australia) in different inner ear stimulation modalities. Originally the actuator was intended for direct perilymph stimulation after stapedotomy using a piston prosthesis. A possible alternative application is the stimulation of middle ear structures or the round window (RW). Here the perilymph stimulation w...

Journal: :Acta otorrinolaringologica espanola 2006
M Martín Félix Trujillo J Eduardo Ramírez

PURPOSE To compare a Teflon prosthesis to a piston-type wire/Teflon prosthesis assessing auditory results post-Stapedectomy. MATERIAL AND METHODS We conducted a randomized controlled blinded clinical study from June 2003 to August 2004 at the Otorhinolaryngology, and Head and Neck Surgical Wards at the highly specialized medical unit of "La Raza" General Hospital National Medical Cen ter in M...

2015
Martin Grossöhmichen Rolf Salcher Hans-Heinrich Kreipe Thomas Lenarz Hannes Maier

This work assesses the efficiency of the Codacs system actuator (Cochlear Ltd., Sydney Australia) in different inner ear stimulation modalities. Originally the actuator was intended for direct perilymph stimulation after stapedotomy using a piston prosthesis. A possible alternative application is the stimulation of middle ear structures or the round window (RW). Here the perilymph stimulation w...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید