نتایج جستجو برای: teoaes

تعداد نتایج: 110  

2012
D. SOI D. BRAMBILLA E. COMIOTTO F. DI BERARDINO E. FILIPPONI M. SOCCI E. SPREAFICO S. FORTI A. CESARANI

Several studies have previously demonstrated that postural changes modify evoked otoacoustic emission. In order to evaluate a possible interaction between eye muscles and ciliated cells in the inner ear, we studied the effects of eye lateralization on the contralateral suppression of transient evoked otoacoustic emissions (TEOAEs). Thirty-eight normal hearing subjects with TEOAEs were recruited...

Journal: :Informatica, Lith. Acad. Sci. 2010
Arturas Janusauskas Vaidotas Marozas Arunas Lukosevicius Leif Sörnmo

Transient evoked otoacoustic emissions (TEOAEs) have been analyzed for objective assessment of hearing function and monitoring of the influence of noise exposure and ototoxic drugs. This paper presents a novel application of the Hilbert–Huang transform (HHT) for detection and time-frequency mapping of TEOAEs. Since the HHT does not distinguish between signal and noise, it is combined with ensem...

2013
Safaa S. Imam Rania A. El-Farrash Hesham M. Taha Helbees E. Bishoy

Aim. To compare targeted neonatal hearing screening (TNHS) and universal neonatal hearing screening (UNHS) since many developing countries, including Egypt, implement selective screening for high-risk neonates. Methods. 150 neonates were assessed; 50 full terms consecutively admitted to the well-baby nursery and 100 neonates consecutively admitted to neonatal intensive care unit (NICU), Ain Sha...

Journal: :The Journal of the Acoustical Society of America 2014
Lynne Marshall Judi A Lapsley Miller John J Guinan Christopher A Shera Charlotte M Reed Zachary D Perez Lorraine A Delhorne Paul Boege

Otoacoustic emission (OAE) tests of the medial-olivocochlear reflex (MOCR) in humans were assessed for viability as clinical assays. Two reflection-source OAEs [TEOAEs: transient-evoked otoacoustic emissions evoked by a 47 dB sound pressure level (SPL) chirp; and discrete-tone SFOAEs: stimulus-frequency otoacoustic emissions evoked by 40 dB SPL tones, and assessed with a 60 dB SPL suppressor] w...

2016
Noor Alaudin Abdul Wahab Suzaily Wahab Abdul Hamid Abdul Rahman Dinsuhaimi Sidek Mohd. Normani Zakaria

OBJECTIVE Electrophysiological studies, which are mostly focused on afferent pathway, have proven that auditory processing deficits exist in patients with schizophrenia. Nevertheless, reports on the suppressive effect of efferent auditory pathway on cochlear outer hair cells among schizophrenia patients are limited. The present, case-control, study examined the contralateral suppression of tran...

Journal: :Journal of the American Academy of Audiology 1995
F E Musiek S P Bornstein W F Rintelmann

The audiologic diagnosis of pseudohypacusis continues to challenge the clinical audiologist. The introduction of otoacoustic emissions (OAEs) to the test repertoire of the audiologist may prove valuable in the evaluation of pseudohypacusis. This report highlights five cases in which transient evoked otoacoustic emissions (TEOAEs) were used to cross-check the validity of subjective audiologic th...

Journal: :iranian rehabilitation journal 0
farzaneh zamiri abdollahi iran, tehran, evin, daneshjoo blvd, kudakyar ave., audiology department of uswr yones lotfi iran, tehran, evin, daneshjoo blvd, kudakyar ave., audiology department of uswr

objectives: otoacoustic emissions (oaes) are sounds that originate in cochlea and are measured in external auditory canal and provide a simple, efficient and non-invasive objective indicator of healthy cochlear function. olivo cochlear bundle (ocb) or auditory efferent system is a neural feedback pathway which originated from brain stem and terminated in the inner ear and can be evaluated non-i...

2016
Prawin Kumar Vibhu Grover Sam Publius A Himanshu Kumar Sanju Sachchidanand Sinha

Objective Contralateral suppression of oto acoustic emission (OAE) is referred as activation of efferent system. Previous literature mentioned about the importance of contralateral suppression of OAEs as a tool to assess efferent system in different groups of population. There is dearth of literature to explore the efferent system function in experienced musicians exposed to rock music using TE...

Journal: :International journal of pediatric otorhinolaryngology 1999
G Paludetti F Ottaviani A R Fetoni A A Zuppa G Tortorolo

OBJECTIVE Early diagnosis and rehabilitation of congenital hearing loss are mandatory in order to achieve a satisfactory linguistic and cognitive development. A universal hearing screening in order to identify congenital hearing losses before 3 months of age is required. METHODS TEOAEs are an easy to perform, short lasting, not invasive and low-cost test with a high sensitivity. 320 at term n...

Journal: :Audiology & neuro-otology 2013
Shaum Bhagat Johnnie Bass Ibrahim Qaddoumi Rachel Brennan Matthew Wilson Jianrong Wu Carlos-Rodriguez Galindo Alessia Paglialonga Gabriella Tognola

The aims of this study were to characterize and quantify time-frequency changes in transient-evoked otoacoustic emissions (TEOAEs) recorded in children diagnosed with retinoblastoma who were receiving carboplatin chemotherapy. A signal processing technique, the wavelet transform (WT), was used to analyze TEOAE waveforms in narrow-band frequency components. Ten children (aged 3-72 months) diagno...

نمودار تعداد نتایج جستجو در هر سال