نتایج جستجو برای: thermoluminescence dosimeters tld

تعداد نتایج: 3413  

2011
M. Giglioli

Since the beginning of its use, radiation has already presented harm, justifying the necessity of controlled use. In order to monitor its effects and even avoid them, dosimetry has arisen. For the purpose of ensured all the necessary safety and monitor areas where there is radiation use, a lot of devices able to identify and quantify many types of radiation were developed. However, some these d...

Journal: :Cumhuriyet Science Journal 2023

Thermal quenching is described as a decrease in luminescence efficiency with increasing measurement temperature. Luminescence intensity decreases heating rates the presence of thermal quenching. In such case, rate to be used measurements becomes important. Lithium fluoride (LiF) type dosimeters have been widely radiation dosimetry for many years. this study, effect was investigated LiF:Mg,Ti (T...

2000
V. P. SINGH N. M. BADIGER R. R. BIHARI

In the present paper, we estimated backscattering factors for the TLD and active personal dosimeters using 662 keV gamma-ray photons on a PMMA surface, which are, for the TLD, 1.12; Dosicard, 1.116; DRD, 0.99; and Saphydose, 1.073, and on a water slab phantom surface; for the TLD, 1.115; Dosicard, 1.112; DRD, 1; and Saphydose, 1.059. The backscattering factor contribution for the Saphydose is n...

Alireza Sadremomtaz, Peyvand Taherparvar Sepideh Gholami

Introduction: Neutrons have many applications in various fields, such as medicine. The important application of neutron in medical science is in Boron Neutron Capture Therapy (BNCT). Because of this, determination of neutron dose and flux is critical for the health maintaining of workers and patients exposed to this beam. The neutron radioisotope sources produce gamma rays in ...

Journal: :Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics 2008
B Hill A J Venning C Baldock

Polymer gel dosimetry undertaken on a multislice CT scanner provides an alternative method to conventional dosimetry measurements. Polymer gel dosimeters were used to measure CT radiation doses and compared to TLD and ionization chamber measurements in different diameter phantoms. CTDI was investigated for each of these phantoms for a range of mAs (100-400 mAs), tube voltage (100-135 kV) and no...

2015
Mostafa Ghomeishi G. Amouzad Mahdiraji F. R. Mahamd Adikan N. M. Ung D. A. Bradley

With interest in the potential of optical fibres as the basis of next-generation thermoluminescence dosimeters (TLDs), the development of suitable forms of material and their fabrication has become a fast-growing endeavour. Present study focuses on three types of Ge-doped optical fibres with different structural arrangements and/or shapes, namely conventional cylindrical fibre, capillary fibre,...

Journal: :Indian journal of experimental biology 2000
A F Stevenson

The decay characteristics of 90Sr-90Y ensure that the mother and daughter nuclides exist in radioactive equilibrium, unless they get discriminated on the basis of their chemical properties, as it happens during metabolism. Although bone is the ultimate organ of deposition, the two nuclides arrive at this target organ over different biokinetic pathways. As 90Y is not excreted, it goes through tr...

2014
Parvin Mohammadyari Mehdi Zehtabian Sedigheh Sina Ali Reza Tavasoli Reza Faghihi

Currently, the use of blood irradiation for inactivating pathogenic microbes in infected blood products and preventing graft-versus-host disease (GVHD) in immune suppressed patients is greater than ever before. In these systems, dose distribution and uniformity are two important concepts that should be checked. In this study, dosimetry of the gamma chamber blood irradiator model Gammacell 3000 ...

2015
Juha H. Koivisto Jan E. Wolff Timo Kiljunen Dirk Schulze Mika Kortesniemi

The aims of this study were to characterize reinforced metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters to assess the measurement uncertainty, single exposure low-dose limit with acceptable accuracy, and the number of exposures required to attain the corresponding limit of the thermoluminescent dosimeters (TLD). The second aim was to characterize MOSFET dosimeter sensitivit...

2015
Raffaele Liuzzi Federica Savino Vittoria D’Avino Mariagabriella Pugliese Laura Cella Gabriele Multhoff

BACKGROUND Purpose of the present work was to investigate thermoluminescent dosimeters (TLDs) response to intraoperative electron radiation therapy (IOERT) beams. In an IOERT treatment, a large single radiation dose is delivered with a high dose-per-pulse electron beam (2-12 cGy/pulse) during surgery. To verify and to record the delivered dose, in vivo dosimetry is a mandatory procedure for qua...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید