نتایج جستجو برای: ti 6al 4v alloy

تعداد نتایج: 83441  

2007
Pedro César Garcia Oliveira Gelson Luis Adabo Ricardo Faria Ribeiro Sicknan Soares da Rocha Fabiano Araújo Ávila Accácio Lins do Valle

The aim of the work was to evaluate the influence of the temperature of investment healting on the tensile strength and Vickers hardness of CP Ti and Ti-6Al-4V alloy casting. Were obtained for the tensile strength test dumbbell rods that were invested in the Rematitan Plus investment and casting in the Discovery machine cast. Thirty specimens were obtained, fifteen to the CP Titanium and fiftee...

2013
Xiaoping Yang Richard Liu

In present work, prediction the effect of nose radius, rz (mm) on the equivalent strain (PEEQ) and surface finish during the machining of titanium alloy (Ti-6Al-4V) through orthogonal cutting process. The results were performed at several of the nose radiuses, rz (mm) while the cutting speed, vc (m/min), feed rate, f (mm/tooth) and depth of cut, d (mm) were remained constant. The equivalent pla...

Journal: :The journal of contemporary dental practice 2007
Khalid A Al Wazzan Ibrahim S Al Hussaini

AIMS The aims of this study were to investigate the influence of commercially pure titanium (PTi) and titanium-aluminum-vanadium (Ti-6Al-4V) alloys (TiA) on the final shade of low-fusing porcelain bonded to them and to compare the shade changes with those of three conventional metal-ceramic systems. METHODS AND MATERIALS A titanium casting unit was used to cast PTi and Ti-6Al-4V alloy specime...

2008
Ken’ichi Yokoyama Katsutoshi Takashima Jun’ichi Sakai

The susceptibility to hydrogen absorption and hydrogen thermal desorption of titanium alloys has been investigated in a neutral 2.0% NaF solution at 37 C under various applied cathodic potentials. Ti-0.2Pd, Ti-6Al-4V and Ti-11.3Mo-6.6Zr-4.3Sn alloys absorb hydrogen under less noble potentials than 1:5V, 1:9V and 1:4V versus a saturated calomel electrode, respectively. The amounts of absorbed hy...

2017
Mohammad Rizviul Kabir Henning Richter

A selective laser melting (SLM)-based, additively-manufactured Ti-6Al-4V alloy is prone to the accumulation of undesirable defects during layer-by-layer material build-up. Defects in the form of complex-shaped pores are one of the critical issues that need to be considered during the processing of this alloy. Depending on the process parameters, pores with concave or convex boundaries may occur...

2015
Moaz H. Ali M. N. M. Ansari

This paper presents a study the effect of nose radius (Rz-mm) on cutting force components and temperatures during the machining simulation in an orthogonal cutting process for titanium alloy (Ti-6Al-4V). The cutting process was performed at various nose radiuses (Rz-mm) while the depth of cut (d-mm), feed rate (fmm/tooth) and cutting speed (vc-m/ min) were remained constant. The main cutting fo...

2016
Hansong Li Chuanping Gao Guoqian Wang Ningsong Qu Di Zhu

The titanium alloy Ti-6Al-4V is used in many industries including aviation, automobile manufacturing, and medical equipment, because of its low density, extraordinary corrosion resistance and high specific strength. Electrochemical machining (ECM) is a non-traditional machining method that allows applications to all kinds of metallic materials in regardless of their mechanical properties. It is...

Journal: :Science and technology of advanced materials 2012
Yoshimitsu Okazaki Hiroyuki Nagata

Metal release from implantable metals and the properties of oxide films formed on alloy surfaces were analyzed, focusing on the highly biocompatible Ti-15Zr-4Nb-4Ta alloy. The thickness and electrical resistance (Rp) of the oxide film on such an alloy were compared with those of other implantable metals. The quantity of metal released during a 1-week immersion test was considerably smaller for ...

2015
Hossein Maleki-Ghaleh Masoud Hafezi Mohammadreza Hadipour Ali Nadernezhad Ermia Aghaie Yashar Behnamian Noor Azuan Abu Osman Xiaohua Liu

In the current study, a sol-gel-synthesized tricalcium magnesium silicate powder was coated on Ti-6Al-4V alloys using plasma spray method. Composition of feed powder was evaluated by X-ray diffraction technique before and after the coating process. Scanning electron microscopy and atomic force microscopy were used to study the morphology of coated substrates. The corrosion behaviors of bare and...

Journal: :Journal of the mechanical behavior of biomedical materials 2011
L E Murr K N Amato S J Li Y X Tian X Y Cheng S M Gaytan E Martinez P W Shindo F Medina R B Wicker

Total knee replacement implants consisting of a Co-29Cr-6Mo alloy femoral component and a Ti-6Al-4V tibial component are the basis for the additive manufacturing of novel solid, mesh, and foam monoliths using electron beam melting (EBM). Ti-6Al-4V solid prototype microstructures were primarily α-phase acicular platelets while the mesh and foam structures were characterized by α(')-martensite wi...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید