نتایج جستجو برای: ti6al4v alloy

تعداد نتایج: 53141  

A. Saatchi, M. Salehi and T. H North, M. Shamanian,

The metallurgical and mechanical properties of Ti6Al4V/(WC-Co) friction welds have ben investigated. The microstructure close to the bondline comprised a mixture of acicular and equiaxed α plus β phases. The diffusion of elements in the welded specimens has been detected. The fracture strengths of Ti6Al4V/(WC-Co) friction welds markedly improved when the cobalt content in the (WC-Co) carbide su...

A. Saatchi, M. Salehi and T. H North, M. Shamanian,

The metallurgical and mechanical properties of Ti6Al4V/(WC-Co) friction welds have ben investigated. The microstructure close to the bondline comprised a mixture of acicular and equiaxed α plus β phases. The diffusion of elements in the welded specimens has been detected. The fracture strengths of Ti6Al4V/(WC-Co) friction welds markedly improved when the cobalt content in the (WC-Co) carbide su...

2017
Ernesto Beltrán-Partida Benjamín Valdéz-Salas Aldo Moreno-Ulloa Alan Escamilla Mario A. Curiel Raúl Rosales-Ibáñez Francisco Villarreal David M. Bastidas José M. Bastidas

BACKGROUND Neovascularization over dental implants is an imperative requisite to achieve successful osseointegration onto implanted materials. The aim of this study was to investigate the effects on in vitro angiogenesis of anodized 70 nm diameter TiO2 nanotubes (NTs) on Ti6Al4V alloy synthesized and disinfected by means of a novel, facile, antibacterial and cost-effective method using super ox...

Journal: :journal of computational & applied research in mechanical engineering (jcarme) 2015
m. azizpour m. ghoreishi a. khorram

this paper was aimed to report the 3d finite element analysis simulation of laser welding process of ti6al4v 1.7 mm sheets in butt joint in order to predict the temperature distribution, hardness, and weld geometry. the butt-joint welds were made using co2 laser with the maximum power of 2.2 kw in the continuous wave mode. a part of the experimental work was carried out to verify the weld geome...

2016
Zhentao Man Dan Sha Shui Sun Tao Li Bin Li Guang Yang Laibo Zhang Changshun Wu Peng Jiang Xiaojuan Han Wei Li

Total hip arthroplasty (THA) is a common procedure for the treatment of end-stage hip joint disease, and the demand for revision THA will double by 2026. Ti6Al4V (Titanium, 6% Aluminum, and 4% Vanadium) is a kind of alloy commonly used to make hip prothesis. To promote the osseointegration between the prothesis and host bone is very important for the revision THA. The peptide Arg-Gly-Asp (RGD) ...

2015
M.S. Mahdipoor H.S. Kirols D. Kevorkov P. Jedrzejowski M. Medraj

Water Droplet Erosion (WDE) as a material degradation phenomenon has been a concern in power generation industries for decades. Steam turbine blades and the compressor blades of gas turbines that use water injection usually suffer from WDE. The present work focuses on studying erosion resistance of TiAl as a potential alloy for turbine blades compared to Ti6Al4V, a frequently used blade alloy. ...

Journal: :journal of modern processes in manufacturing and production 2015
nahid hassanzadeh nemati shiva yasini maryam aryana

different methods have been evaluated for manufacturing the porous ti6al4v alloys according todecreasing stress shielding phenomenon and increasing mechanical compatibility between themetallic components and the host tissue. for this purpose, in this work ti6al4v alloy chips werepressed under 400 mpa pressure and then samples were categorized and heated into two groups at1000 and 1150℃ under a ...

Journal: :Biomaterials 2007
Jin-Woo Park Kwang-Bum Park Jo-Young Suh

The biocompatibility of calcium ion (Ca)-incorporated Ti6Al4V alloy implants, produced by hydrothermal treatment using a Ca-containing solution, was investigated. The surface characteristics were evaluated by scanning electron microscopy, thin-film X-ray diffractometry, Auger electron spectroscopy, and stylus profilometry. The viability of MC3T3-E1 cells on Ca-incorporated machined Ti6Al4V surf...

Journal: :Biomaterials 2004
Jay R Goldberg Jeremy L Gilbert

The mechanical and electrochemical behavior of the surface oxides of CoCrMo and Ti6Al4V alloys during fracture and repassivation play an important role in the corrosion of the taper interfaces of modular hip implants. This behavior was investigated in one group of CoCrMo and Ti6Al4V alloy samples passivated with nitric acid and another group coated with a novel TiN/AlN coating. The effects of m...

2015
M Surmeneva E Chudinova M Syrtanov

This study is focused on the use of radio frequency magnetron sputtering to modify the surface of porous Ti6Al4V alloy fabricated via additive manufacturing technology. The hydroxyapatite (HA) coated porous Ti6Al4V alloy was studied in respect with its chemical and phase composition, surface morphology, water contact angle and hysteresis, and surface free energy. Thin nanocrystalline HA film wa...