نتایج جستجو برای: tuned liquid dampers

تعداد نتایج: 245096  

2002
Ahsan Kareem

Serviceability of buildings is affected by excessive acceleration experienced at the top floors in wind storms that may cause discomfort to the occupants. To ensure functional performance of tall buildings it is important to keep the frequency of objectionable motion levels below the discomfort threshold. This paper addresses a new approach that facilitates mitigation of wind induced motion of ...

Journal: :Philosophical transactions. Series A, Mathematical, physical, and engineering sciences 2015
V Jaksic C S Wright J Murphy C Afeef S F Ali D P Mandic V Pakrashi

In this paper, we experimentally study and compare the effects of three combinations of multiple tuned liquid column dampers (MTLCDs) on the dynamic performance of a model floating tension-leg platform (TLP) structure in a wave basin. The structural stability and safety of the floating structure during operation and maintenance is of concern for the performance of a renewable energy device that...

2014
Bo Chen Wei-hua Guo Peng-yun Li Wen-ping Xie

This paper presented an overview on the dynamic analysis and control of the transmission tower-line system in the past forty years. The challenges and future developing trends in the dynamic analysis and mitigation of the transmission tower-line system under dynamic excitations are also put forward. It also reviews the analytical models and approaches of the transmission tower, transmission lin...

2007
Kalyan Raj

It is very well known that tuned mass dampers are engineered to minimise the vibrations in buildings in earthquake prone areas and in some cases machinery [1]. This paper evaluates the utility of Tuned Mass Dampers in passenger cars. For the same suspension system, addition of a tuned mass was found to reduce the transmissibility by a considerable amount. Addition of a tuned mass also helps in ...

Journal: :روش های عددی در مهندسی (استقلال) 0
فیاض رحیم زاده روفویی و آرش ملکان f. rahimzadeh rofooei and a. malakan

tuned liquid dampers (tld) are among passive control devices that have been used to suppress the vibration of structures in recent years. these structures must be adequately presentable as an equivalent single degree of freedom system with long fundamental period. the tld, located at the top floors of the structure, can dissipate the external input energy into the system through the sloshing ef...

A. Farshidianfar, S. Soheili,

This paper investigates the optimized parameters for the tuned liquid column dampers to decrease the earthquake vibrations of high-rise buildings. Considering soil effects, the soilstructure interaction (SSI) is involved in this model. The Tuned Liquid Column Damper (TLCD) is also utilized on the roof of the building. Since the TLCD is a nonlinear device, the time domain analysis based on nonli...

2014
Nimisha Rao Jerome J. Connor

The major concern in the construction industry in constructing tall structures is vibration due to wind and earthquake. Tuned mass dampers are an effective and practical ways to reduce the effect of vibration in structures. This thesis presents a tool, which simulates the effect of tuned mass dampers on the structure. This tool has been proposed to form a part of the website, moment.mit.edu. Ja...

Journal: :Environment. Technology. Resources. Proceedings of the International Scientific and Practical Conference 2015

Journal: :مهندسی عمران فردوسی 0
پیمان اشرفی جواد علامتیان

this paper deals with new method for designing the tuned mass dampers (tmd) with considering both transient and steady state responses, simultaneously. this formulation is presented for undamped vibrations. for this purpose, the absolute value of the structural displacement ratio is minimized numerically. this procedure leads to optimum value of tmd's specifications. for numerical verification,...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید