نتایج جستجو برای: underground cable

تعداد نتایج: 26983  

2012
Mamdooh S. Al-Saud

The influence of thermal circuit parameters on a buried underground cable is investigated using an ANFIS (adaptive neuro-fuzzy inference system). Finite element solution of the heat conduction equation is used, combined with artificial intelligence methods. The cable temperature depends on several parameters, such as the ambient temperature, the currents flowing through the conductor and the re...

There is an increasing need to determine accurately the strength properties of tendons for an effective ground control on mines and underground structures as well as on modelling simulations. The strength properties of cables, used as cable bolts, have been evaluated mainly by their ultimate tensile strength, as this kind of test can be carried out in the field as well as in the laboratory. Onl...

2006
J. R. Riba Ruiz X. Alabern Morera

In this paper the influence of the metallic sheath in the magnetic field generated by underground single core power cables is studied. When dealing with underground power cables, sheath circulating currents can be induced. These currents produce power losses in the sheaths and decrease the ampacity (capacity of carrying current) of the cables. The circulating sheath currents generate a magnetic...

2005
P L Lewin

This paper discusses data acquisition, transmission and processing methodologies for continuous on-line monitoring of partial discharges in high voltage cable systems. A PD continuous on-line monitoring system for underground cable circuits using capacitive couplers, LiNbO3 electro-optic modulators, laser, optical switch and optical fibers has been developed. Future research will consider effec...

2002
B. Jiang

Accurate, real-time information about the aging status of the power distribution cable network can save the power industry millions of dollars lost due to line failures and premature replacement of cables. Hence, a novel, semiautonomous robotic sensor platform has been developed for monitoring underground, power distribution cable systems. A segmented, legged modular configuration allows the ro...

2011
L. Hao P. L. Lewin S. G. Swingler

The condition of a 400 kV underground FF cable route within the National Grid transmission network has been monitored by Drallim pressure, temperature and load current measurement system. These three measured variables are used as parameters to describe the condition of the cable system. In the regression analysis the temperature and load current of the cable circuit are used as independent var...

2003
T. K. Saha P. Purkait

Deterioration of the underground power cables insulation has been established to be caused by electrical, thermal and environmental stresses. With the degradation of dielectric strength of the insulation, the underground cables will not be able to function optimally or as planned. As a supplement to the existing dissipation factor and other conventional cable diagnostic measurements, the Decay ...

Journal: :International Journal of Electrical and Computer Engineering (IJECE) 2013

Journal: :International Journal for Research in Applied Science and Engineering Technology 2019

2011
Amin Mahmoudi

This paper presents a new approach for the determination of underground cable ampacity that considers natural convection of air inside a conduit and heterogeneous soil around the conduit, and compares calculated results with conduit-less considerations. It shows how ampacity of a buried cable is affected by thickness of the soil above it, and by the surrounding soil’s heterogeneity and thermo-p...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید