PURPOSE Metal objects present in x-ray computed tomography (CT) scans are accompanied by physical phenomena that render CT projections inconsistent with the linear assumption made for analytical reconstruction. The inconsistencies create artifacts in reconstructed images. Metal artifact reduction algorithms replace the inconsistent projection data passing through metals with estimates of the tr...
PURPOSE To evaluate a method of reducing computed tomography (CT) metal artifacts due to the Fletcher-Suit applicator. METHODS AND MATERIALS We apply a projection-interpolation algorithm to CT images containing artifacts from the brachytherapy applicator. Regions of projection data containing the applicator are interpolated, removing the metal from the projections. A new image is then reconst...
دراین رساله برخی از فضاهای باناخی که دارای خاصیت یکنواختی هستند معرفی و مورد بررسی قرار می گیرند. که از جمله می توان به فضاهای باناخ بطور یکنواخت هموار، یکنواخت مدور موضعی (ضعیف)، یکنواخت مدور (ur)، تقریبا" یکنواخت مدور (nur)، یکنواخت مدور -ur` دلتا) و نیز فضاهای باناخی که دارای خاصیت یکنواختی (ua) a و یکنواختی (ukk)k-k هستند اشاره نمود . که هریک از فضاهای مذکور دارای خواص جالبی هستند که برخی ا...
Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...
Karin Andersson (2018): Metal Artifacts in Computed Tomography – impact of reduction methods on image quality and radiotherapy treatment planning. Örebro Studies in Medicine 172. Degradation of image quality by metal artifacts is a common problem in computed tomography (CT) imaging, which can limit the diagnostic value of a CT examination and also introduce inaccuracies in radiotherapy (RT) tre...
BACKGROUND Metal objects implanted in the bodies of patients usually generate severe streaking artifacts in reconstructed images of X-ray computed tomography, which degrade the image quality and affect the diagnosis of disease. Therefore, it is essential to reduce these artifacts to meet the clinical demands. METHODS In this work, we propose a Gaussian diffusion sinogram inpainting metal arti...
Metal in CT-imaged objects drastically reduces the quality of these images due to the severe artifacts it can cause. Most metal artifacts reduction (MAR) algorithms consider the metal-affected sinogram portions as the corrupted data and replace them via sophisticated interpolation methods. While these schemes are successful in removing the metal artifacts, they fail to recover some of the edge ...
X-ray computed tomography (CT) images of patients bearing metal intracavitary applicators or other metal foreign objects exhibit severe artifacts including streaks and aliasing. We have systematically evaluated via computer simulations the impact of scattered radiation, the polyenergetic spectrum, and measurement noise on the performance of three reconstruction algorithms: conventional filtered...