نتایج جستجو برای: varian accelerator

تعداد نتایج: 18438  

2017
Kimberley Legge Peter B. Greer Paul J. Keall Jeremy T. Booth Sankar Arumugam Trevor Moodie Doan T. Nguyen Jarad Martin Daryl John O'Connor Joerg Lehmann

PURPOSE The Trans-Tasman Radiation Oncology Group (TROG) 15.01 Stereotactic Prostate Adaptive Radiotherapy utilizing Kilovoltage intrafraction monitoring (SPARK) trial is a multicenter trial using Kilovoltage Intrafraction Monitoring (KIM) to monitor prostate position during the delivery of prostate radiation therapy. KIM increases the accuracy of prostate radiation therapy treatments and allow...

2015
Hamid Reza Baghani Seyed Mahmoud Reza Aghamiri Seyed Rabi Mahdavi Mohammad Esmail Akbari Hamid Reza Mirzaei

The specific design of the mobile dedicated intraoperative radiotherapy (IORT) accelerators and different electron beam collimation system can change the dosimetric characteristics of electron beam with respect to the conventional accelerators. The aim of this study is to measure and compare the dosimetric characteristics of electron beam produced by intraoperative and conventional radiotherapy...

Journal: :Medical physics 2012
C Borges M Zarza-Moreno E Heath N Teixeira P Vaz

PURPOSE The most recent Varian(®) micro multileaf collimator (MLC), the High Definition (HD120) MLC, was modeled using the BEAMNRC Monte Carlo code. This model was incorporated into a Varian medical linear accelerator, for a 6 MV beam, in static and dynamic mode. The model was validated by comparing simulated profiles with measurements. METHODS The Varian(®) Trilogy(®) (2300C/D) accelerator m...

2010
Sanaz Hariri Majid Shahriari

Due to intensive use of multileaf collimators (MLCs) in clinics, finding an optimum design for the leaves becomes essential. There are several studies which deal with comparison of MLC systems, but there is no article with a focus on offering an optimum design using accurate methods like Monte Carlo. In this study, we describe some characteristics of MLC systems including the leaf tip transmiss...

Journal: :iranian journal of medical physics 0
mona zolfaghari department of physics, faculty of science, k. n. t university of technology, tehran, iran mahmood sedaghatizadeh department of physics, faculty of science, k. n. t university of technology, tehran, iran

introduction electron linear accelerator (linac) can be used for neutron production in boron neutron capture therapy (bnct). bnct is an external radiotherapeutic method for the treatment of some cancers. in this study, varian 2300 c/d linac was simulated as an electron accelerator-based photoneutron source to provide a suitable neutron flux for bnct. materials and methods photoneutron sources w...

2017
Silvia Vargas Castrillón Francisco Cutanda Henríquez

The International Atomic Energy Agency Technical Reports Series-398 code of practice for dosimetry recommends measuring photon percentage depth dose (PDD) curves with parallel-plate chambers. This code of practice was published before flattening filter-free (FFF) beams were widely used in clinical linear accelerators. The choice of detector for PDD measurements needs to be reassessed for FFF be...

2006
M. Dinesh Kumar N. Thirumavalavan D. Venugopal Krishna M. Babaiah

To evaluate the utility of Dynalog file information for planar dose verification in IMRT QA, a program is developed to convert Dynalog file data to DMLC field files. For this study, five predefined fluencies are planned and delivered using Varian, Eclipse 3D planning system and 6MV photon beam of Varian, Clinac DMX linear accelerator. To measure planar dose distribution, Kodak, EDR2 films are e...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید