نتایج جستجو برای: ahmed glaucoma valve

تعداد نتایج: 136798  

Journal: :European journal of ophthalmology 2007
I A Chaudhry F A Shamsi J Morales

PURPOSE Orbital cellulitis (OC) as a complication of implanted aqueous drainage devices (ADD) for glaucoma is an uncommon phenomenon. The authors report two cases of infectious OC in patients with a history of congenital glaucoma and placement of ADD. METHODS Clinical records of two patients with ADD who subsequently developed OC were reviewed for presenting symptoms, signs, medical and surgi...

2013
Michiko Miki Mari Ueki Tetsuya Sugiyama Shota Kojima Tsunehiko Ikeda

PURPOSE To report the short-term efficacy and safety of the transfer of an Ahmed(™) glaucoma valve (AGV™) tube from the vitreous into the anterior chamber, in a patient with neovascular glaucoma who had undergone pars plana AGV(™) implantation and ultimately needed a silicone oil tamponade. CASE A 41-year-old male with proliferative diabetic retinopathy in both eyes was referred to us for tre...

2015
Ji Won Seo Jong Yeon Lee Dong Heun Nam Dae Yeong Lee

Purpose. To compare the changes in corneal endothelial cells after pars plana Ahmed glaucoma valve (AGV) implantation with those after the anterior chamber AGV implantation for refractory glaucoma. Methods. The medical records of 18 eyes with pars plana implantation of AGV (ppAGV) were reviewed retrospectively and were compared with 18 eyes with the anterior chamber AGV (acAGV) implant. The pre...

2014
Mohammad Pakravan Mohsen Afroozifar Shahin Yazdani

PURPOSE To determine corneal biomechanical changes following major glaucoma procedures. METHODS In a prospective comparative case series, corneal biomechanical properties were assessed using the Ocular Response Analyzer (ORA, Reichert Inc., Depew, New York, USA) before and 3 months after surgery in 89 eyes of 89 patients undergoing trabeculectomy + mitomycin C (MMC) (23 eyes, group 1), phacot...

Journal: :Archivos de la Sociedad Espanola de Oftalmologia 2010
M J Suárez-Fernández E Gutiérrez-Díaz A Julve San Martín M F Fernández-Reyes E Mencía-Gutiérrez

PURPOSE To evaluate intraocular pressure (IOP) and visual acuity (VA) results after glaucoma drainage device (GDD) implantation combined with simultaneous pars plana vitrectomy (PPV). MATERIAL AND METHODS Retrospective review of 8 eyes (7 patients). The diagnosis was neovascular glaucoma (NVG) secondary to proliferative diabetic retinopathy in 4 eyes, in a which a double plate Molteno implant...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید