نتایج جستجو برای: anisotropy coefficient

تعداد نتایج: 202052  

2018
Chenxi Han Changchun Chai Qingyang Fan Jionghao Yang Yintang Yang

The structural, mechanical, anisotropic, electronic, and thermal properties of t-Si₃N₄, t-Si₂GeN₄, t-SiGe₂N₄, and t-Ge₃N₄ in the tetragonal phase are systematically investigated in the present work. The mechanical stability is proved by the elastic constants of t-Si₃N₄, t-Si₂GeN₄, t-SiGe₂N₄, and t-Ge₃N₄. Moreover, they all demonstrate brittleness, because B/G < 1.75, and v < 0.26. The elastic a...

Journal: :The Journal of chemical physics 2006
Xiaobing Feng Brian B Laird

The crystal-metal interfacial free energy for a six-site model of succinonitrile [N triple bond C-(CH(2))(2)-C triple bond N] has been calculated using molecular-dynamics simulation from the power spectrum of capillary fluctuations in interface position. The orientationally averaged magnitude of the interfacial free energy is determined to be (7.0+/-0.4)x10(-3) J m(-2). This value is in agreeme...

1998
Benjamin D. Wandelt Eric Hivon Krzysztof M. Górski

Much attention has been given to the problem of estimating cosmological parameters from the Cl measured by future experiments. Many of the approaches which are being used either invoke poorly controlled approximations or are computationally expensive. We derive exact results as well as fast and highly accurate approximations for mapping a theoretical model onto the observed power spectrum coeff...

1995
F. Matthäus

A transversally driven isotropic ferromagnet being under the influence of a static external and an uniaxial internal anisotropy field is studied. We consider the dissipative Landau-Lifshitz equation as the fundamental equation of motion and treat it in 1 + 1 dimensions. The stability of the spatially homogeneous magnetizations against inhomogeneous perturbations is analyzed. Subsequently the dy...

2004
M A Shpot H W Diehl

The large-n expansion is developed for the study of critical behaviour of d-dimensional systems at m-axial Lifshitz points with an arbitrary number m of modulation axes. The leading non-trivial contributions of O(1/n) are derived for the two independent correlation exponents η L2 and η L4 , and the related anisotropy index θ. The series coefficients of these 1/n corrections are given for genera...

Journal: :The Journal of chemical physics 2014
Adrian H Hill Henrik Jacobsen J Ross Stewart Feng Jiao Niels P Jensen Sonja L Holm Hannu Mutka Tilo Seydel Andrew Harrison Kim Lefmann

Samples of nanoscale hematite, α-Fe2O3, with different surface geometries and properties have been studied with inelastic time-of-flight neutron scattering. The 15 nm diameter nanoparticles previously shown to have two collective magnetic excitation modes in separate triple-axis neutron scattering studies have been studied in further detail using the advantage of a large detector area, high res...

Journal: :Journal of biomedical optics 2006
Moritz Friebel André Roggan Gerhard Müller Martina Meinke

The absorption coefficient mu(a), scattering coefficient mu(s), and anisotropy factor g of diluted and undiluted human blood (hematocrit 0.84 and 42.1%) are determined under flow conditions in the wavelength range 250 to 1100 nm, covering the absorption bands of hemoglobin. These values are obtained by high precision integrating sphere measurements in combination with an optimized inverse Monte...

Journal: :Physical review. E, Statistical, nonlinear, and soft matter physics 2002
Vicente Garzó

Tracer diffusion in a granular gas in simple shear flow is analyzed. The analysis is made from a perturbation solution of the Boltzmann kinetic equation through first order in the gradient of the mole fraction of tracer particles. The reference state (zeroth-order approximation) corresponds to a Sonine solution of the Boltzmann equation, which holds for arbitrary values of the restitution coeff...

Journal: :Magnetic resonance in medicine 2004
Hongxia Ren Qiang Shen Juergen Bardutzky Marc Fisher Timothy Q Duong

Partial-volume effects (PVE) in stroke imaging could hinder proper delineation of normal, ischemic, and at-risk tissues. Cerebral-blood-flow (CBF) and apparent diffusion coefficient (ADC) were measured at high and low resolution (HR = 128 x 128, LR = 64 x 64) in focal ischemia in rats during the acute phase. The data were evaluated for PVE on ischemic tissue classification on a pixel-by-pixel b...

Journal: :The Journal of chemical physics 2013
Mario Heidernätsch Michael Bauer Günter Radons

Anisotropic diffusion processes emerge in various fields such as transport in biological tissue and diffusion in liquid crystals. In such systems, the motion is described by a diffusion tensor. For a proper characterization of processes with more than one diffusion coefficient, an average description by the mean squared displacement is often not sufficient. Hence, in this paper, we use the dist...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید