نتایج جستجو برای: borated polyethylene

تعداد نتایج: 31603  

Journal: :Journal of Research of the National Bureau of Standards Section A: Physics and Chemistry 1976

Journal: :polyolefins journal 2015
christophe daniel simona longo gaetano guerra

monolithic aerogels of high molecular weight polyethylene (mw= 3x106- 6x106 g/mol) have been prepared by solvent extraction with supercritical carbon dioxide from thermoreversible gels prepared in decalin. these low density and highly porous aerogels present an apparent porosity up to 90%. the aerogel morphology observed by scanning electron microscopy (sem) is characterized by spherulitic stru...

2009
Hong Chul Lim Ji Hoon Bae Jin Ho Hwang Seung Joo Kim Ji Yeol Yoon

We report the case of a polyethylene tibial post fracture in a 72-year-old woman 14 months after a Scorpio posterior-stabilized (PS) total knee arthroplasty. The polyethylene wear was found around the fracture site of the post, especially over the anterior aspect of the post base. The failure mechanism of the post fracture in the present case was anterior impingement with excessive wear over th...

Journal: :Acta orthopaedica Belgica 2003
H P Bhinda S P Sarkar

The authors report a case of early failure of a total hip arthroplasty with dissociation of the polyethylene liner of an S-ROM Oblong Cup*, which presented as a dislocation. Initial closed reduction of the dislocation was not possible. Open exploration of the hip revealed that the modular Poly Dial* polyethylene acetabular liner had become dislodged from the acetabular cup. The liner was revise...

2011
Gang Chen Carl Richard Soderberg Vazrik Chiloyan

Polymer fiber drawing creates fibers with enhanced thermal conductivity and strength compared to bulk polymer because drawing aligns the molecular chains. I optimize the polymer fiber drawing method in order to achieve polymer fibers that are drawn to lengths exceeding 1cm and develop a method to cut and store them for future experimental purposes. With lengths exceeding 1cm, starting with leng...

2013
Mark Heldreth

For a given applied compressive load across the tibio-femoral joint, wear is therefore primarily a function of the area of polyethylene under cross-shear and the total relative sliding distance between the femoral and polyethylene insert articulating surfaces. Andriacchi et al. described the significant degree of relative sliding which can occur between the femoral and tibial articulation surfa...

Journal: :Clinical chemistry 1976
H S Schiller M A Brammall

We describe a rapid, reliable radioimmunoassay for unconjugated estriol in plasma. Polyethylene glycol (Carbowax 6000) is used to separate antibody-bound and free steroid. The assay is sensitive (25 pg for standards), precise, and accurate. At high and low concentrations of estriol, intra-assay coefficients of variation were 7.1% and 7.6%, respectively, and inter-assay coefficients of variation...

2017
Emmanuel Richaud Bruno Flaconnèche Jacques Verdu Emmanuel RICHAUD Bruno FLACONNÈCHE Jacques VERDU

This paper reports solubility and diffusivity data for soy and rapeseed methyl esters in polyethylene together with comparisons with methyl oleate and linoleate. These data showed that there is no significant difference in diffusivity and solubility between all these penetrants. Data were used to discuss the reliability of predictive models for diffusion and solubility of additive type molecule...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید