نتایج جستجو برای: calibration standards

تعداد نتایج: 163640  

2000
Christopher S. Ruf

A novel technique has been developed to verify the absolute accuracy and relative stability of a spaceborne microwave radiometer’s calibration using a statistical analysis of the measured Earth brightness temperatures (TBs). This procedure relies solely on the final, main beam-referenced TBs and so tests the complete end-to-end system calibration, including instrument temperature and non-linear...

2011
S. Parkinson

Machine tool calibration requires a wide range of measurement techniques that can be carried out in many different sequences. Planning a machine tool calibration is typically performed by a subject expert with a great understanding of International standards and industrial best-practice guides. However, it is often the case that the planned sequence of measurements is not the optimal. Therefore...

Journal: :iranian journal of pharmaceutical sciences 0
zahra ramezani jundishapur university of medical sciences, toxicology research center, ahvaz, iran jundishapur university of medical sciences, faculty of pharmacy, ahvaz, iran nasrin aghel jundishapur university of medical sciences, faculty of pharmacy, ahvaz, iran roohollah shiralipour department of chemistry, center of researches & sciences, eslamic azad university, ahvaz, iran reza zadeh dabbagh department of chemistry, center of researches & sciences, eslamic azad university, ahvaz, iran

in this study, 60 composite samples of dill and onion from two different cultivated areas in khozestan province, iran, were collected and analyzed for the presence and determination of lead and cadmium by flame atomic absorption spectrometry. samples were burned according to aoac at 450 °c, and the residue was dissolved in nitric acid. lead and cadmium contents were determined using calibration...

Journal: :Analytical chemistry 2000
S Y Hu M A Arnold J M Wiencek

Digital Fourier filtering is used to produce a temperature-insensitive univariate calibration model for measuring lysozyme in aqueous solutions. Absorbance spectra over the 5000-4000 cm-1 spectral range are collected for lysozyme standards maintained at 14 degrees C. These spectra are used to compute the calibration model while a set of spectra collected at temperatures ranging from 4 to 24 deg...

2006
Craig Heimbach

A neutron spectrometer was acquired for use in the measurement of National Institute of Standards and Technology neutron fields. The spectrometer included options for the measurement of low and high energy neutrons, for a total measurement range from 0.01 eV up to 17 MeV. The spectrometer was evaluated in calibration fields and was used to determine the neutron spectrum of an Americium-Berylliu...

2009
Douglas Kent Rytting

The degree to which measurement accuracy in a vector network analyzer can be improved through error correction is dependent on a number of factors. Modern error correction methods have improved the system accuracy and simplified the calibration procedure. Methods are in place to determine the accuracy of error corrected measurements. And the quality of the calibration standards is key to system...

2010
Raymond S. Turgel

National Bureau of Standards Gaithersburg, MD 20899 To provide a phase meter calibration service, a phase angle calibration standard has been developed at NBS. This standard is a signal. generator with two sinusoidal outputs and uses direct digital synthesis to generate the signals. The phase angle between the two sinusoids is determined by the input parameters in the calculation of the sets of...

2001
R. González-Riestra

This paper deals with the definition of the input fluxes used for the calibration of the IUE Final Archive. The method adopted consists on the determination of the shape of the detector’s sensitivity curves using IUE low resolution observations with model fluxes of the DA white dwarf G191–B2B. A scale factor was then determined so that the IUE observations of some bright OAO–2 standards match t...

Journal: :Radiation protection dosimetry 2005
P Kotrappa L R Stieff P Volkovitsky

The National Institute of Standards and Technology (NIST) polyethylene-encapsulated 226Ra/222Rn emanation (PERE) standards (old SRM 4968 and new SRMs 4971, 4972, and 4973) provide precise radon emanation rate, certified to a high degree of accuracy (approximately to 2%). Two new SRM 4973 standards containing totally 1036 Bq (0.028 microCi) of 226Ra, emanate 0.114 Bq (3.08 pCi) of 222Rn per min....

2009
Peter A. Parker Geoffrey Vining Sara R. Wilson John L. Szarka Nels G. Johnson

The calibration of measurement systems is a fundamental but under-studied problem within industrial statistics. The origins of this problem go back to basic chemical analysis based on NIST standards. In today’s world these issues extend to mechanical, electrical, and materials engineering. Often, these new scenarios do not provide ”gold standards” such as the standard weights provided by NIST. ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید