نتایج جستجو برای: capillary rise method

تعداد نتایج: 1783235  

Journal: :iranian red crescent medical journal 0
bulent yardimci department of internal medicine, istanbul florence nightingale hospital, istanbul, turkey; department of internal medicine, istanbul florence nightingale hospital, istanbul, turkey. tel: +90-2123756565, fax: +90-2122244982 rumeyza kazancioglu department of nephrology, bezmialem vakif university, faculty of medicine, istanbul, turkey

conclusions the early signs and symptoms of iscls may be subtle; therefore the diagnosis can easily be missed and prompt treatment of the syndrome may be postponed. thus, the clinician must consider iscls in differential diagnosis in cases of hypotension, hemoconcentration, and hypoalbuminemia. case presentation we present a 58-year-old female who presented with peripheral edema, leg pain, and ...

2008
Shufang Jiang Yaohu Kang Zeqiang Sun

Measurements of porosity and pore size distribution provide important data on the physical properties of soils. This paper presents a digital image method for the analysis of soil pores. In the analysis of soil thin sections, the image threshold separating pore space from the surrounding solid, as well as the capillary pore size threshold separating air pores and capillary pores, was obtained b...

Journal: :The New phytologist 2000
H Schneider N Wistuba H J Wagner F Thurmer U Zimmermann

The acropetal water refilling kinetics of the dry xylem of branches (up to 80 cm tall) of the resurrection plant Myrothamnus flabellifolia were determined with high temporal resolution by observation of light refraction at the advancing water front and the associated recurving of the folded leaves. To study the effect of gravity on water rise, data were acquired for cut upright, horizontal and ...

A common approach in resolving enantiomers of chiral basic drugs by capillary electrophoresis (CE) is to use cyclodextrins (especially their anionic derivatives) as chiral selector in the acidic buffer (pH ≤ 3) in normal or reversed (carrier) mode. Then, some organic modifiers are added to the buffer solution if the resolution is not satisfactory. In case of cetirizine (CTN), applying the same ...

A common approach in resolving enantiomers of chiral basic drugs by capillary electrophoresis (CE) is to use cyclodextrins (especially their anionic derivatives) as chiral selector in the acidic buffer (pH ≤ 3) in normal or reversed (carrier) mode. Then, some organic modifiers are added to the buffer solution if the resolution is not satisfactory. In case of cetirizine (CTN), applying the same ...

Journal: :Journal of chromatography. A 2007
Frantisek Kvasnicka Michal Voldrich Josef Vyhnálek

An on-line coupled capillary isotachophoresis-capillary zone electrophoresis method for the determination of glycyrrhizin in liqueurs is described. The optimised electrolyte system was 5 mM HCl+11 mM epsilon-aminocaproic acid+0.05% hydroxyethylcellulose+30% methanol (leading electrolyte), 5 mM caproic acid+30% methanol (terminating electrolyte) and 20 mM caproic acid+10 mM histidine+0.1% hydrox...

Journal: :Proceedings in applied mathematics & mechanics 2021

We investigate how the walls of cylindrical capillaries affect velocity rising gas bubbles various diameters. Of course, as capillary diameter increases, bubble will approach case free rising. Such systematic experiments on rise in capillaries, which ratio and is varied from one towards smaller values, can hardly be found literature. Experiments within system water/air have been conducted stagn...

2006
C. Kurt Svihla Hong Xu

Three different test cases involving free surface flows with surface tension were investigated with ANSYS CFX. Transient analyses were performed in all cases. The three cases were: (1) oscillations of a twodimensional cylindrical rod; (2) rise of liquid in a capillary; and (3) rise of an air bubble train through stagnant water. The mesh resolution, timestep, and solver settings required to obta...

Journal: :Journal of Circuits, Systems, and Computers 2009
Guoqing Chen Eby G. Friedman

With higher operating frequencies, transmission lines are required to model global onchip interconnects. In this paper, an accurate and efficient solution for the transient response at the far end of a transmission line based on a direct pole extraction of the system is proposed. Closed form expressions of the poles are developed for two special interconnect systems: an RC interconnect and an R...

2003
D J Bakewell H Morgan

This paper presents a technique for measuring and quantifying the dielectrophoretic collection of sub-micron particles on planar microelectrode arrays. Fluorescence microscopy and video recording is used to measure the number of particles collecting on an electrode as a function of time for various experimental parameters, such as applied electrode voltage and frequency. Video images are proces...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید