نتایج جستجو برای: chemiluminescence method
تعداد نتایج: 1634362 فیلتر نتایج به سال:
A fully automated microfluidic-based detection system for the rapid determination of insulin concentration through a chemiluminescence immunoassay has been developed. The microfluidic chip used in the system is a double-layered polydimethylsiloxane device embedded with interconnecting micropumps, microvalves, and a micromixer. At a high injection rate of the developing solution, the chemilumine...
During the process of phagocytosis, human leukocytes emit a burst of luminescence which can be measured in a liquid scintillation spectrometer. The enzyme superoxide dismutase, which removes superoxide anions (O(2.)), inhibited this chemiluminescence by 70% at a concentration of 100 mug/ml. The enzyme did not inhibit phagocytosis. These results support other studies indicating that O(2.) is ela...
چکیده ندارد.
2-(2-Aminoethyl)-1-methylpyrrolidine and N-(3-aminopropyl)pyrrolidine (NAPP) were found to be selective and sensitive derivatization reagents for carboxylic acid by high-performance liquid chromatography (HPLC) with electrogenerated chemiluminescence detection using tris(2,2'-bipyridine)ruthenium(II). Free fatty acids and ibuprofen were used as model compounds of carboxylic acids, and the deriv...
The Fe(II)-catalyzed oxidation of luminol has been a well-accepted chemiluminescence method for the trace and ultra-trace analysis of Fe(II) and Fe(III) in natural waters. Investigation into this chemiluminescence system has shown that COlg) is essential to Fe-catalyzed luminol chemiluminescence. In absence of CO2(g) there is no chemiluminescent signal. These reactions worked well in the past b...
A sensitive flow injection chemiluminescence (FL-CL) method for the determination of cephalosporin antibiotics, was developed. The method was based on that cephalosporin antibiotics could enhance the CL reaction of glyoxal and KMnO(4) in sulfuric acid. Method development included the optimization of reagent concentrations and flow-rate. Under the optimized conditions, three cephalosporin antibi...
The significance of microsomal vitamin E in protecting against the free-radical process of lipid peroxidation was evaluated with the low-level-chemiluminescence technique in microsomal fractions from vitamin E-deficient and control rats. The induction period that normally precedes the ascorbate/ADP/Fe3+-induced lipid peroxidation was taken as reflecting the microsomal vitamin E content and was ...
Rapid, simple and highly sensitive flow-injection (FI) chemiluminescence (CL) and flow-injection electrogenerated chemiluminescence (ECL) methods were developed for the determination of escitalopram oxalate (ESC), a selective serotonin reuptake inhibitor used as an antidepressant drug. The CL method was based on the CL reaction of ESC with acidic cerium(IV) and tris(2,2'-bipyridyl)ruthenium(II)...
BACKGROUND Rapid commercial assays, including nucleic acid amplification tests and immunoassays for Clostridium. difficile toxins, have replaced the use of older assays. They are included in a two-step algorithm diagnosis, including first the detection of the glutamate dehydrogenase (GDH) as a screening method and second the detection of toxins as a confirmatory method. Although assays that det...
Various radical-scavenging activities of thiamin and thiamin diphosphate (TDP) were found in some in vitro experiments. Thiamin and TDP caused considerable suppressive effects on superoxide generation in hypoxanthine and xanthine oxidase system which was measured by a sensitive chemiluminescence method using 2-methyl-6-[p-methylphenyl]-3,7-dihydroimidazo[1,2-alpha]pyrazin-3-one (MCLA), and thei...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید