نتایج جستجو برای: clinical dosimetry
تعداد نتایج: 1168967 فیلتر نتایج به سال:
PURPOSE Well-known defect of TG-43 based algorithms used in brachytherapy is a lack of information about interaction cross-sections, which are determined not only by electron density but also by atomic number. TG-186 recommendations with using of MBDCA (model-based dose calculation algorithm), accurate tissues segmentation, and the structure's elemental composition continue to create difficulti...
BACKGROUND Megavoltage beams used in radiotherapy are contaminated with secondary electrons. Different parts of linac head and air above patient act as a source of this contamination. This contamination can increase damage to skin and subcutaneous tissue during radiotherapy. Monte Carlo simulation is an accurate method for dose calculation in medical dosimetry and has an important role in optim...
BACKGROUND Scintillation camera imaging is used for treatment planning and post-treatment dosimetry in liver radioembolization (RE). In yttrium-90 (90Y) RE, scintigraphic images of technetium-99m (99mTc) are used for treatment planning, while 90Y Bremsstrahlung images are used for post-treatment dosimetry. In holmium-166 (166Ho) RE, scintigraphic images of 166Ho can be used for both treatment p...
It is the purpose of this study to evaluate how self-expanding stents (SESs) affect esophageal cancer radiation planning target volumes (PTVs) and dose delivered to surrounding organs at risk (OARs). Ten patients were evaluated, for whom a SES was placed before radiation. A computed tomography (CT) scan obtained before stent placement was fused to the post-stent CT simulation scan. Three method...
The National Institute of Standards and Technology (NIST) introduced a national standard for air kerma strength of the ThreaSeed Model 200 103Pd source (the only 103Pd seed available until 1999) in early 1999. Correct implementation of the NIST-99 standard requires the use of dose rate constants normalized to this same standard. Prior to the availability of this standard, the vendor's calibrati...
Portal dosimetry (PD) was performed for 181 fields from 14 IMRT plans of various clinical sites at gantry zero and source-to-detector distance (SDD) of 100 cm. PD was realized using aSi1000 electronic portal imaging device (EPID) and portal dose prediction (PDP) algorithm implemented in Eclipse treatment planning system (TPS). Agreement of PDP predicted and EPID measured photon fluence/dose dis...
Treatment options for patients with thyroid cancer that is no longer sensitive to iodine therapy are limited. Those treatments which currently exist are associated with significant toxicity. The SELIMETRY trial (EudraCT No 2015-002269-47) aims to investigate the role of the MEK inhibitor Selumetinib in resensitizing advanced iodine refractory differentiated thyroid cancer to radioiodine therapy...
The use of Cone beam CT (CBCT) systems for Image Guided Radiotherapy is rapidly expanding in the developed world. With its use comes concern for the increased risks of additional radiation exposure. Quantification of the imaging dose is necessary in order to report, optimise and justify CBCT exposures. This article reviews the current methods of dose measurement and calculation including dose m...
Introduction: In radiotherapy, methods of treatment planning are becoming increasingly more complicated. This requires verification of the doses delivered to increasingly smaller and more precise regions. Radiotherapy techniques are continuously employing smaller and smaller field sizes to deliver tighter radiation doses with higher therapeutic ratios, generating interest among researchers to p...
OBJECTIVES/HYPOTHESIS Voice rest is frequently recommended following surgical disruption of vocal fold epithelium, but patients report variable adherence to voice rest recommendations. The objective of this study was to assess the clinical utility of an ambulatory vocal dosimeter for measuring adherence to voice rest recommendations. STUDY DESIGN Outcomes research. METHODS Part 1: To determ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید