نتایج جستجو برای: compressive strain

تعداد نتایج: 239017  

Journal: :journal of rehabilitation in civil engineering 2013
a. hemmati a. kheyroddin m.k. sharbatdar

high performance fiber reinforced cementitious composite (hpfrcc) materials exhibit strain hardening behavior with multiple cracking under tensile loading. in this paper, experimental and parametric studies are performed to assess the influence of using hpfrcc material instead of normal concrete in reinforced concrete beams. after calibrating the experimental results, the analytical results inc...

2015
Damar Rastri Adhika Masaki Tanaka Takeshi Daio Kenji Higashida

The dislocation shielding field at a crack tip was experimentally proven at the atomic scale by measuring the local strain in front of the crack tip using high-resolution transmission electron microscopy (HRTEM) and geometric phase analysis (GPA). Single crystalline (110) silicon wafers were employed. Cracks were introduced using a Vickers indenter at room temperature. The crack tip region was ...

2011
Abhijeet Paul Gerhard Klimeck

The impact of uniaxial and hydrostatic stress on the ballistic thermal conductance (jl) and the specific heat (Cv) of [100] and [110] Si nanowires are explored using a Modified Valence Force Field phonon model. An anisotropic behavior of jl and isotropic nature of Cv under strain are predicted for the two wire orientations. Compressive (tensile) strain decreases (increases) Cv. The Cv trend wit...

Hadi Meidani,

A plasticity-fracture constitutive model is presented for prediction of the behavior of confined plain concrete. A three-parameter yield surface is used to define the elastic limit. Volumetric plastic strain is defined as hardening parameter, which together with a nonlinear plastic potential forms a non-associated flow rule. The use of non-associated flow rule improves the prediction of the dil...

2000
R. K. Rowe

Local strain measurements opposite gravel contacts and around a single isolated perforation are reported for a high-density-polyethylene pipe (320 mm outside diameter, 32 mm thick) typical of that commonly used as part of the leachate collection system in municipal solid waste landfills. Emphasis is given to examining the localized effect of coarse gravel contacts on pipe strain and the strain ...

2017
Jin Suk Yoo Kung-Rock Kwon Kwantae Noh Hyeonjong Lee Janghyun Paek

PURPOSE The design of the attachment must provide an optimum stress distribution around the implant. In this study, for implant overdentures with a bar/clip attachment or a locator attachment, the stress transmitted to the implant in accordance with the change in the denture base length and the vertical pressure was measured and analyzed. MATERIALS AND METHODS Test model was created with epox...

Journal: :Journal of the mechanical behavior of biomedical materials 2016
S Kolaczek C Hewison S Caterine M X Ragbar A Getgood K D Gordon

This study presents a method to evaluate three-dimensional strain in meniscal tissue using medical imaging. Strain is calculated by tracking small teflon markers implanted within the meniscal tissue using computed tomography imaging. The results are presented for strains in the middle and posterior third of the medial menisci of 10 human cadaveric knees, under simulated physiologically relevant...

Journal: :Nano letters 2016
Martin Hetzl Max Kraut Julia Winnerl Luca Francaviglia Markus Döblinger Sonja Matich Anna Fontcuberta I Morral Martin Stutzmann

We demonstrate the selective area growth of GaN-(Al,Ga)N core-shell nanowire heterostructures directly on Si(111). Photoluminescence spectroscopy on as-grown nanowires reveals a strong blueshift of the GaN band gap from 3.40 to 3.64 eV at room temperature. Raman measurements relate this shift to compressive strain within the GaN core. On the nanoscale, cathodoluminescence spectroscopy and scann...

2014
Keun-Hyeok Yang Ju-Hyun Mun Hey-Zoo Hwang

This study examined the stress-strain behavior of 10 calcium hydroxide (Ca(OH)2)-activated Hwangtoh concrete mixes. The volumetric ratio of the coarse aggregate (V agg) and the water-to-binder (W/B) ratio were selected as the main test variables. Two W/B ratios (25% and 40%) were used and the value of V agg varied between 0% and 40.0%, and 0% and 46.5% for W/B ratios of 25% and 40%, respectivel...

Journal: :Bone 2014
Haisheng Yang Kent D Butz Daniel Duffy Glen L Niebur Eric A Nauman Russell P Main

The in vivo mouse tibial loading model has been increasingly used to understand the mechanisms governing the mechanobiological responses of cancellous and cortical bone tissues to physical stimuli. Accurate characterization of the strain environment throughout the tibia is fundamental in relating localized mechanobiological processes to specific strain stimuli in the skeleton. MicroCT-based fin...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید