نتایج جستجو برای: density calibration

تعداد نتایج: 463947  

Journal: :Annals of statistics 2015
Gourab Mukherjee Iain M Johnstone

We consider estimating the predictive density under Kullback-Leibler loss in an ℓ0 sparse Gaussian sequence model. Explicit expressions of the first order minimax risk along with its exact constant, asymptotically least favorable priors and optimal predictive density estimates are derived. Compared to the sparse recovery results involving point estimation of the normal mean, new decision theore...

2012
Iain M. Johnstone

We consider estimating the predictive density under KullbackLeibler loss in an l0 sparse Gaussian sequence model. Explicit expressions of the first order minimax risk along with its exact constant, asymptotically least favorable priors and optimal predictive density estimates are derived. Compared to the sparse recovery results involving point estimation of the normal mean, new decision theoret...

2002
R. Schubert

A method is presented for the measurement of the electron density in an experimental plasma fusion device by means of microwave reflectometry. Since microwaves with increasing frequency can penetrate deeper into the plasma, it is possible to sample the electron density distribution by frequency-sweep techniques. For the first time the system allows a non-contact measurement of the electron dens...

2007
M Najmzadeh

In this paper, a new and simple silicon straight tube is tested as a fluid density sensor. The tube structure has a hexagonal cross section. The fabrication process consists of anisotropic silicon etching and silicon fusion bonding. A tube structure with a length of 2.65 cm was tested. The sample volume is 9.3 μL. The first three modes of vibrations were investigated with a laser Doppler vibrom...

2001
Shyhchang S. Huang

The current definition of intrinsic viscosity ([riD, and its application in the universal calibration method, applies to polymeric materials with molecular weight (MW) >>1,000. However, there have been numerous discussions regarding the [11]of low MW oligomers. Difficulties can be encountered at very low MW, because the [1"1] in some cases becomes negative, which in theory is impossible. A new ...

Journal: :Remote Sensing 2016
Patricio Xavier Molina Gregory Asner Mercedes Farjas Abadía Juan Carlos Ojeda Manrique Luis Alberto Sánchez Diez Renato Valencia

Mapping aboveground carbon density in tropical forests can support CO2 emission monitoring and provide benefits for national resource management. Although LiDAR technology has been shown to be useful for assessing carbon density patterns, the accuracy and generality of calibrations of LiDAR-based aboveground carbon density (ACD) predictions with those obtained from field inventory techniques sh...

1997
P. R. Young E. Landi R. J. Thomas

The CHIANTI database was described by Dere et al. (1997, hereafter Paper I) and the present paper applies the atomic data to the study of extreme ultraviolet emission lines found in the SERTS-89 active region spectrum published by Thomas & Neupert (1994). Firstly, the emission line ratios that are insensitive to density and temperature are used to check both the quality of the atomic data and t...

Journal: :Biosensors & bioelectronics 2009
Emre Ozkumur Ayça Yalçin Marina Cretich Carlos A Lopez David A Bergstein Bennett B Goldberg Marcella Chiari M Selim Unlü

A primary advantage of label-free detection methods over fluorescent measurements is its quantitative detection capability, since an absolute measure of adsorbed material facilitates kinetic characterization of biomolecular interactions. Interferometric techniques relate the optical phase to biomolecular layer density on the surface, but the conversion factor has not previously been accurately ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید