نتایج جستجو برای: elastography

تعداد نتایج: 5434  

Journal: :Oncology 2017
Norihisa Yada Toshiharu Sakurai Tomohiro Minami Tadaaki Arizumi Masahiro Takita Satoru Hagiwara Hiroshi Ida Kazuomi Ueshima Naoshi Nishida Masatoshi Kudo

OBJECTIVE In order to evaluate the influence of liver inflammation on liver stiffness measurement (LSM) by the simultaneous use of shear wave and strain imaging (combinational elastography), shear wave and strain imaging were compared before and after initial therapy for autoimmune hepatitis (AIH). METHODS Nine AIH patients initially treated with steroid were enrolled. Transient elastography ...

2015
Carlo Cappelli Ilenia Pirola Elena Gandossi Annamaria Formenti Barbara Agosti Maurizio Castellano

The aim of the present prospective study was to evaluate the predictive value of elastography in benign thyroid nodules of patients affected by Hashimoto's thyroiditis (HT). From January 2011 to January 2012, 242 nodules in patients affected by HT were submitted to fine needle aspiration cytology (FNAC). All of the patients underwent sonography and elastography performed before FNAC. 230 (95%) ...

Journal: :Asian Pacific journal of cancer prevention : APJCP 2014
Ying Fu Yun-Fei Shi Kun Yan Yan-Jie Wang Wei Yang Guo-Shuang Feng

Ultrasonography is non-invasive and can give useful clues in the diagnosis of cervical lymphadenopathy, However, differential diagnosis is difficult in some situations even combined with color Doppler imaging. The present study was conducted to evaluate the clinical value of real time elastography in patients with unexplained cervical lymphadenopathy using a quantitative method. From May 2011 t...

Journal: :Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine 2008
Orpheus Kolokythas Thomas Gauthier Anna T Fernandez Hua Xie Brian A Timm Carlos Cuevas Manjiri K Dighe Lee M Mitsumori Matt F Bruce Daniel A Herzka Gaurav K Goswami R Torrance Andrews Kelly M Oas Theodore J Dubinsky Bill H Warren

OBJECTIVE The purpose of this study was to evaluate the technical feasibility of ultrasound-based elastography as a tool for assessing the size and shape of the coagulation necrosis caused by radio frequency ablation (RFA) probes using expandable electrodes ex vivo as well as in a patient with a liver metastasis. METHODS A commercially available expandable RFA probe was used to create a 3-cm ...

Journal: :Ultrasound in medicine & biology 2013
Pezhman Foroughi Hyun-Jae Kang Daniel A Carnegie Mark G van Vledder Michael A Choti Gregory D Hager Emad M Boctor

Ultrasound transducers are commonly tracked in modern ultrasound navigation/guidance systems. In this article, we demonstrate the advantages of incorporating tracking information into ultrasound elastography for clinical applications. First, we address a common limitation of freehand palpation: speckle decorrelation due to out-of-plane probe motion. We show that by automatically selecting pairs...

Journal: :Medical physics 2011
Elijah E W Van Houten D vR Viviers M D J McGarry P R Perriñez I I Perreard J B Weaver K D Paulsen

PURPOSE Recently, the attenuating behavior of soft tissue has been addressed in magnetic resonance elastography by the inclusion of a damping mechanism in the methods used to reconstruct the resulting mechanical property image. To date, this mechanism has been based on a viscoelastic model for material behavior. Rayleigh, or proportional, damping provides a more generalized model for elastic en...

2009
Carmen Kut Caitlin Schneider Naima Carter-Monroe Li-Ming Su Emad Boctor Russell Taylor Michael I. Miga Kenneth H. Wong

Purpose: To compare the accuracy of detecting tumor location and size in the prostate using both manual palpation and ultrasound elastography (UE). Methods: Tumors in the prostate were simulated using both synthetic and ex vivo tissue phantoms. 25 participants were asked to provide the presence, size and depth of these simulated lesions using manual palpation and UE. Ultrasound images were capt...

2016
Susana Rodrigues

l l i i h n a w s e iver fibrosis is, undoubtedly, one of the main prognostic facors in liver disease because it determines the development f cirrhosis and its subsequent complications.1 Classically, liver biopsy has been considered the old-standard for liver fibrosis assessment.2 There are limtations associated to liver biopsy, namely sampling bias, bserver variability among pathologists and p...

Journal: :Physics in medicine and biology 2014
Heiko Tzschätzsch Selcan Ipek-Ugay Jing Guo Kaspar-Josche Streitberger Enno Gentz Thomas Fischer Robert Klaua Michael Schultz Jürgen Braun Ingolf Sack

Elastography is capable of noninvasively detecting hepatic fibrosis by imposing mechanical stress and measuring the viscoelastic response in the liver. Magnetic resonance elastography (MRE) relies on time-harmonic vibrations, while most dynamic ultrasound elastography methods employ transient stimulation methods. This study attempts to benefit from the advantages of time-harmonic tissue stimula...

Journal: :Ultrasound in medicine & biology 2004
Raffaella Righetti Jonathan Ophir Seshadri Srinivasan Thomas A Krouskop

The feasibility of using elastography for experimentally estimating and imaging the Poisson's ratio of porous media under drained and undrained conditions was investigated. Using standard elastographic procedures, static and time-sequenced poroelastograms (strain ratio images) of homogeneous cylindrical gelatin and commercially available tofu samples were generated under sustained applied axial...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید