نتایج جستجو برای: femoral length

تعداد نتایج: 346817  

2011
Yevgeniy Palatnik S. Robert Rozbruch

Background. The use of an external fixator for the purpose of distraction osteogenesis has been applied to a wide range of orthopedic problems caused by such diverse etiologies as congenital disease, metabolic conditions, infections, traumatic injuries, and congenital short stature. The purpose of this study was to analyze our experience of utilizing this method in patients undergoing a variety...

Journal: :Orthopedics 2018
Markus Heinecke Fabian Rathje Frank Layher Georg Matziolis

Although cementless revision arthroplasty of the hip has become the gold standard, revision arthroplasty of the distal femur is controversial. This study evaluated the anchoring principles of different femoral revision stem designs in extended bone defect situations, taking into account the anatomical conditions of the proximal and distal femur, and the resulting primary stability. Cementless p...

Journal: :Orthopedics 2017
Brandon Hood Laura Blum Sven A Holcombe Stewart C Wang Andrew G Urquhart James A Goulet Joseph D Maratt

Accurate sagittal alignment of the femoral component in total knee arthroplasty is crucial for prosthesis longevity, improved function, and patient satisfaction. However, there is variation in the techniques used to attain optimal sagittal femoral component placement in total knee arthroplasty. Femoral component flexion in imageless navigation is based on the mechanical axis rather than the dis...

Journal: :Orthopedics 2013
Joseph D Maratt Alexander E Weber Michael Knesek John R Lien Andrew G Urquhart

Despite the overwhelming clinical success of total hip arthroplasty, complications such as leg-length discrepancy can be a significant cause of functional impairment and patient dissatisfaction. Multiple intraoperative techniques are available for measuring femoral limb length; however, many require additional invasive hardware and those that do not are less accurate at measuring limb length. T...

Journal: :BMC Musculoskeletal Disorders 2005
Kai-Jow Tsai Po-Wen Shen William C Hutton

BACKGROUND Open methods for removal of femoral interlocking nails involve an incision (up to 10 cm) over the trochanter to find the tip of the nail. The distal locking screws are some times difficult to palpate and an incision (up to about 5 cm) is often needed for exposure. Intra-operative fluoroscopy is often used as an adjunct technique to minimize the surgical wound. However, patients and s...

Journal: :Orthopedics 2011
Santiago A Lozano-Calderón Samuel Kenan

Wide resection and reconstruction of tumors of the proximal tibia in the pediatric population are challenging procedures. The use of hinged, expandable prostheses may cause early closure of the distal femoral growth plate, which may increase the risk of limb discrepancy already present in this population. Between 1991 and 2001, 2 girls and 1 boy, aged 6, 6, and 4 years, respectively, were diagn...

2012
Michael E Berend John B Meding Peter Davis

Outcomes following femoral reconstruction during revision total hip arthroplasty (THA) may be influenced by femoral deformity, fixation interface and implant type. The purpose of this study was to determine the long-term clinical and radiographic outcomes of a series of 461 femoral reconstructions with a calcar replacement prosthesis performed over a 21-year period. Multivariate analysis was pe...

Journal: :Clinical orthopaedics and related research 2007
James A DeLullo Eric Thomas Timothy E Cooney Sharon J McConnell James O Sanders

Clinical studies of patients treated for slipped capital femoral epiphysis have found limited functional impairment and femoral neck deformity causing eventual coxarthrosis. Since patient-focused assessments minimize bias and reflect health-related quality of life status, we coupled their use to a clinical examination to obtain a more patient-centered picture of slipped capital femoral epiphyse...

2017
Kang-Il Kim Sang Hak Lee Chanil Bae Sung Hae Bae

Purpose The purpose of this study was to compare the geometry and position of the femoral tunnel between the anteromedial portal (AMP) and outside-in (OI) techniques after anatomic single-bundle anterior cruciate ligament (ACL) reconstruction. Materials and Methods We evaluated 82 patients undergoing single-bundle ACL reconstruction with hamstring autografts using either the AMP (n=40) or OI ...

Journal: :The Journal of bone and joint surgery. British volume 1988
G Hägglund B Bylander L I Hansson G Selvik

Early closure of the growth plate after fixing a slipped upper femoral epiphysis is often regarded as favourable since, if growth of the femoral neck continues, the metal may lose its grip on the epiphysis with the possibility of further slipping. However, in the young child early fusion may result in leg length discrepancy and limited motion. The hook-pin (Hansson 1982) permits continued growt...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید