The aim of this study was to evaluate the depth of curing of 10 contemporary blue light-activated dental flowable materials at several opacities, influenced by different irradiation times using FT-IR spectroscopy. Fifty-five specimens (n = 5) with a 5-mm diameter and 1-mm thickness of translucent (Opallis Flow T), yellowed (Master Flow A2; Opallis Flow A2; Natural Flow A2; Fluroshield Yellowed)...
OBJECTIVES Light-curing of resin-based materials (RBMs) increases the pulp chamber temperature, with detrimental effects on the vital pulp. This in vitro study compared the temperature rise under demineralized human tooth dentin during light-curing and the degrees of conversion (DCs) of three different RBMs using quartz tungsten halogen (QTH) and light-emitting diode (LED) units (LCUs). MATER...
The aim of this study was to evaluate the effect of light-curing devices (Halogen/HAL, Light Emitting Diodes/LED, Argon Laser/LAS and Plasma Arc/PAC) and aging procedures (Mechanical Cycling/MC, Thermal Cycling/TC, Storage/S, MC+TC and MC+TC+S) on the micro-hardness of bottom/B and top/T surfaces of 2-mm-high composite resin cylinders. The Knoop microhardness test (25 g, 20 s) on both B and T w...
Effect of light curing modes and light curing time on the microhardness of a hybrid composite resin.
AIMS The aim of this in vitro study was to evaluate the influence of light curing modes and curing time on the microhardness of a hybrid composite resin. METHODS AND MATERIALS Forty-five Z250 composite resin specimens (3M-ESPE Dental Products, St. Paul, MN, USA) were randomly divided into nine groups (n=5): three polymerization modes (conventional-550 mW/cm2; light-emitting diodes (LED)-360 m...
OBJECTIVE To compare the polymerization effectiveness of two resin composites cured with a quartz tungsten halogen (QTH) lamp or a light emitting diodes (LED) unit. STUDY DESIGN Filtek Z250 (3M ESPE) and Spectrum TPH (Dentsply DeTrey) resin composites were placed in 9 mm deep and 4 mm wide metallic molds and cured using the QTH light Hilux 200 (Benlioglu) or the LED unit Smartlite IQ (Dentspl...
The aim of this in vitro study was to evaluate the influence of light-curing units and different sample thicknesses on the microhardness of a composite resin. Composite resin specimens were randomly prepared and assigned to nine experimental groups (n = 5): considering three light-curing units (conventional quartz tungsten halogen [QTH]: 550 mW/cm(2) - 20 s; high irradiance QTH: 1160 mW/cm(2) -...
The aim of this study was to assess the influence of different light-emitting diodes (LED) light-curing devices for bonding orthodontic brackets, using the shear bond strength and analysis of adhesive remnant index (ARI). Crowns from 60 bovine incisors received brackets bonded with Transbond XT. Specimens were divided into 4 groups (n=15) according to the light-curing procedures: HL = control, ...
Using the push-out test, this study evaluated the bond strength of the composite resin Z250 (3M/ESPE) photoactivated with the XL2500 (3M/ESPE) quartz-tungsten-halogen light-curing unit with different curing protocols: soft-start (150 mW/cm² for 2 s (S2), 3 s (S3), 5 s (S5), 10 s (S10) or 15 s (S15), followed by 700 mW/cm² for 15 s; pulse-delay (150 mW/cm² for 2 s (P2), 3 s (P3), 5 s (P5), 10 s ...
OBJECTIVE The aim of this study is to evaluate the effect of composite preheating and polymerization mode on degree of conversion (DC), microhardness (KHN), plasticization (P), and depth of polymerization (DP) of a bulk fill composite. METHODS Forty disc-shaped samples (n = 5) of a bulk fill composite were prepared (5 × 4 mm thick) and randomly divided into 4 groups according to light-curing ...
This study evaluated the Knoop hardness and polymerization depth of a dual-cured resin cement, light-activated at different distances through different thicknesses of composite resin. One bovine incisor was embedded in resin and its buccal surface was flattened. Dentin was covered with PVC film where a mold (0.8-mm-thick and 5 mm diameter) was filled with cement and covered with another PVC fil...