نتایج جستجو برای: head phantom

تعداد نتایج: 183965  

2016
Jean‐Pierre Mege Sun Wenzhao Attila Veres Guillaume Auzac Ibrahima Diallo Dimitri Lefkopoulos

The purpose of this investigation was to evaluate the dose on megavoltage CT (MVCT) images required for tomotherapy. As imaging possibilities are often used before each treatment and usually used several times before the session, we tried to evaluate the dose delivered during the procedure. For each scanning mode (fine, normal, and coarse), we first established the relative variation of these d...

2017
Jae Won Park Se An Oh Ji Woon Yea Min Kyu Kang

A three-dimensional (3D)-printed customized bolus (3D bolus) can be used for radiotherapy application to irregular surfaces. However, bolus fabrication based on computed tomography (CT) scans is complicated and also delivers unwanted irradiation. Consequently, we fabricated a bolus using a 3D scanner and evaluated its efficacy. The head of an Alderson Rando phantom was scanned with a 3D scanner...

Journal: :Nihon Hoshasen Gijutsu Gakkai zasshi 2012
Tsuyoshi Kudo Kaoru Ono Kengo Furukawa Sachie Fujimoto Yukio Akagi Tadashi Koyama Yutaka Hirokawa

The aim of this study was to compare the setup difference measured with ExacTrac X-ray 6D (ETX6D) and cone-beam computed tomography (CBCT) for non-invasive fractionated radiotherapy. Setup data were collected on a Novalis Tx treatment unit for both a head phantom and patients with intracranial tumors and a pelvic phantom and patients with prostate cancer. Initially, setup was done for a phantom...

Mahmoud Allahverdi Mohammad Hasan Zahmatkesh Tayeb Allahverdi Pourfallah,

Introduction Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of Gamma Knife in homogeneous and inhomogeneous phantoms were compared with eac...

2017
Jun Li Wenyin Shi David Andrews Maria Werner-Wasik Bo Lu Yan Yu Adam Dicker Haisong Liu

PURPOSE The study was aimed to compare online 6 degree-of-freedom image registrations of TrueBeam cone-beam computed tomography and BrainLab ExacTrac X-ray imaging systems for intracranial radiosurgery. METHODS Phantom and patient studies were performed on a Varian TrueBeam STx linear accelerator (version 2.5), which is integrated with a BrainLab ExacTrac imaging system (version 6.1.1). The p...

2011
Sylvia Garny Werner Rühm Maria Zankl Franz M Wagner Herwig G Paretzke

BACKGROUND The Monte Carlo code GEANT4 was used to implement first steps towards a treatment planning program for fast-neutron therapy at the FRM II research reactor in Garching, Germany. Depth dose curves were calculated inside a water phantom using measured primary neutron and simulated primary photon spectra and compared with depth dose curves measured earlier. The calculations were performe...

2016
Yannick Poirier Mauro Tambasco

We present an experimental validation of a kilovoltage (kV) X-ray source characterization model in an anthropomorphic phantom to estimate patient-specific absorbed dose from kV cone-beam computed tomography (CBCT) imaging procedures and compare these doses to nominal weighted CT-dose index (CTDIw) dose estimates. We simulated the default Varian on-board imager 1.4 (OBI) default CBCT imaging pro...

2015
David A. Tovar Wang Zhan Sunder S. Rajan Qinghui Zhang

PURPOSE A novel phantom for image quality testing for functional magnetic resonance imaging (fMRI) scans is described. METHODS The cylindrical, rotatable, ~4.5L phantom, with eight wedge-shaped compartments, is used to simulate rest and activated states. The compartments contain NiCl2 doped agar gel with alternating concentrations of agar (1.4%, 1.6%) to produce T1 and T2 values approximating...

2010
Christoph Fürweger Christian Drexler Markus Kufeld Alexander Muacevic Berndt Wowra

The image-guided CyberKnife radiosurgery system is apable of tracking spinal targets without fiducial implants. Recently, a new version of this fiducial-free image guidance modality ("enhanced Xsight spine tracking") has been introduced. We assessed the accuracy of this novel technique versus its precursor in a comparative phantom study. The CyberKnife consists of a 6 MV linac on a six-axis rob...

2008
W. X. Yan K. J. Mullinger M. J. Brookes R. W. Bowtell Peter Mansfield

Introduction Functional magnetic resonance imaging (fMRI) generates large artefacts in concurrent electroencephalography (EEG) recordings that can significantly compromise EEG data quality (1-2). While much effort has been applied in studying the temporal variation of the artefact waveforms produced by time-varying magnetic field gradients (2-3), the spatial variation of the artefact voltage ac...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید