نتایج جستجو برای: iodide ion selective electrode
تعداد نتایج: 461721 فیلتر نتایج به سال:
Novel biscrowns 1 and 2 were synthesized from 13-membered azobenzocrown ethers containing bromoalkylenoxy chains in para position relative to the azo group. The synthesized diester molecules are dodecylmethylmalonic acid derivatives differing by the linker length. The synthesized compounds have the potential of being used as sodium ionophores in ion-selective electrodes. They were characterized...
Ion-selective electrodes have been applied to analysis of blood electrolytes with some success. However, currently available ion-selective electrode systems tend to be elaborate and expensive. We describe a clinical electrolyte analyzer in which inexpensive ion-selective electrodes are used. The elec‘trodes are in the configuration of thin wires and are all solid in construction. They may be di...
A simple automated method for the estimation of ammonia in perchloric acid supernate of blood or plasma using an ion-selective electrode (Orion Ammonia-selective electrode, Model 95-10) is described. The reliability of the proposed method has been checked against an ion-exchange resin procedure, which has been chosen as a standard procedure. Regression equation and correlation coefficient for t...
Ion-Selective Biosensors In article 2202141, Sam Emaminejad and co-workers develop a touch-based noninvasive system to monitor lithium-based pharmacotherapy. It utilizes thin organohydrogel lithium ion-selective electrode (TOH-ISE) that has dehydration-resistant properties, minimizing signal drift, allowing for sweat collection. The is successfully validated on patient under therapy, demonstrat...
in this work we introduce a practical use of synthesized schiff base metal complex in sensing application. a new perchlorate-selective electrode based on the complex n, n'-4-nitro-phenylmethanebis-(salicylaldiminato) copper (ii) [cul] as the membrane carrier was developed. the electrode exhibits a good nernstian slope of -55.0 ± 1.0 mv/decade and a linear range of for perchlorate. the limit o...
We have evaluated the electric characteristics of an organic surfactant material, n-Cethyl-trimethyl-ammonium Bromide (C16TAB) to fabricate the p-n homo-junction. This C16TAB was dissolved in the pure water, where the potassium iodide (KI) was added. The impurities adaptation has been processed in this mixed solution with the application of voltage. The KI is ionized in the water and the potass...
a novel potentiometric ion-selective pvc membrane sensor for analysis of atorvastatin (at) in pharmaceutical preparations based on atorvastatin-(tetraphenyl borate), (at-(tpb)2) as sensing element, tetraphenyl borate as additive and tris-2-ethyl-hexyl phosphate (top) as plasticizer solvent was prepared. the electrode shows a good nernestian response over the concentration range of 0.09–5586 µg ...
The preparation and assessment of a crown ether covalently grafted onto MoS2 as an ion-selective electrode for sodium ions in biological fluids is presented.
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید