نتایج جستجو برای: ir detectors

تعداد نتایج: 101662  

2014
Y. Hui Z. Qian G. Hummel M. Rinaldi

This paper reports on the first demonstration of an ultra-high resolution (~371 pW/Hz1/2) uncooled infrared (IR) detector based on a high frequency (136 MHz) Aluminum Nitride (AlN) piezoelectric resonant micro-plate completely released from the substrate and supported by two nanoscale Platinum (Pt) anchors. For the first time, fully metallic tethers were employed to support the freestanding vib...

Journal: :The Journal of Experimental Medicine 1981
J T Rosenbaum N E Adelman H O McDevitt

Immune response (Ir) gene products control immunologic function at several critical sites. We administered in vivo a monoclonal antibody reactive with I-Ak to F1 mice with the genotype H-2k/b. These treated mnice made a markedly reduced antibody response to antigen (H,G)-A--L, under the control of I-Ak, but not to antigen (T,G)-A--L, under the control of I-Ab. This relative specificity was lost...

Journal: :The Journal of Experimental Medicine 1982
H Y Tse J J Mond D L Longo

We examined the effects of the developmental milieu on the capacity of B cells to undergo immune response gene-controlled, T cell-dependent polyclonal proliferation. Although I-Aq poly(Glu60 Ala30 Tyr10)n (GAT)-nonresponder T cells developing in a responder environment become phenotypic GAT-responders, I-Aq B cells remain unresponsive to GAT, even after maturation in a GAT-responder animal. Con...

Journal: :journal of dentistry, tehran university of medical sciences 0
ts. jafarzadeh kashi m. erfan dc. watts

objective: the use of hema as a biocompatible material in dentin bonding systems and its potential for clinical applications has been well established. excess water can affect conversion of bonding resins. the aim of this study was to survey the effect of water on the degree of conversion of hema by fourier transform infra-red spectroscopy (ft-ir). materials and methods: in this experimental st...

ژورنال: مواد پرانرژی 2016

Abstract high-performance liquid chromatography (HPLC) are including systems used for separation of explosive mixtures that despite the advantages of rapid analysis, low sample volume, and low consumption organic solvent, in use for complex matrices need to improve the selectivity and sensitivity stationary phase. One of the methods to improve selectivity and sensitivity is choosing the appr...

ژورنال: سنجش و ایمنی پرتو 2015

Upon increasing needs and vast application of neutron detectors, especially in nuclear reactors and growing number of linear accelerators, design and manufacturing of neutron detectors is a serious demand. The aim of this project is building neutron detectors capable of compensating gamma and temperature response in a radiation media. A special thermocouple coated with Boron carbide at the junc...

سعید محمدی, ,

  Yrast states in mirror nuclei 55Co and 55Ni have been populated with a radioactive ion beam using the Isotope Separator On-Line method. A shielded array of 7 Compton suppressed germanium detectors recorded reaction gamma-rays. For channel selection, an array of 128 independent silicon detectors was used to differentiate exit channels with different number of proton and alpha particles emitted...

Journal: :Philosophical transactions. Series A, Mathematical, physical, and engineering sciences 2014
François Simoens Jérôme Meilhan

The development of terahertz (THz) applications is slowed down by the availability of affordable, easy-to-use and highly sensitive detectors. CEA-Leti took up this challenge by tailoring the mature infrared (IR) bolometer technology for optimized THz sensing. The key feature of these detectors relies on the separation between electromagnetic absorption and the thermometer. For each pixel, speci...

1999
M. Seidel

After six years of operation the electron proton collider HERA had reached a luminosity of 1:4 10 cm s , very close to the design value. We present an overview on the HERA upgrade project that pursues the goal to further increase the luminosity three-fold by the year 2000. The increase is achieved by reducing the beam cross sections at the IP to 120 30 m (RMS values). If furthermore design curr...

In this report, ultraviolet (UV) detectors were fabricated based on zinc oxide thin films. The epitaxial growth of zinc oxide thin films was carried out on bare glass substrate with preferred orientation to (002) plane of wurtzite structure through radio frequency sputtering technique. The structural properties indicated a dominant peak at 2θ=34.28º which was matched with JCPDS reference card N...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید