نتایج جستجو برای: mach zehnder interferometer

تعداد نتایج: 16120  

Journal: :Optics letters 2009
Shilong Pan Jianping Yao

We propose and demonstrate a simple method to generate ultrawideband (UWB) pulses in the optical domain using a chirped intensity modulator and an asymmetric Mach-Zehnder interferometer (AMZI). Polarity- and shape-switchable UWB Gaussian monocycle, doublet, and triplet pulses with fractional bandwidths of 158%, 134%, and 100% and center frequencies of 6.52, 9.78, and 10.1 GHz are experimentally...

2015
Vipul Agarwal Vijayshri Chaurasia

In present times, the protection of Optical signal data is becoming very important as large amount of internet data is transferred through Optical fibres. The data can be easily protected by encrypting data before transmission. There many different techniques for optical signal encryption. In this paper, we survey on existing methods used in optical signal encryption. Keywords— Fibre Bragg Grat...

2002
R. Delhuille C. Champenois M. Büchner L. Jozefowski C. Rizzo G. Trénec J. Vigué

We have constructed an atom interferometer of the Mach-Zehnder type, operating with a supersonic beam of lithium. Atom diffraction uses Bragg diffraction on laser standing waves. With first order diffraction, our apparatus has given a large signal and a very good fringe contrast (74%), which we believe to be the highest ever observed with thermal atom interferometers. This apparatus will be app...

Journal: :Optics express 2016
Chong Zhang Paul A Morton Jacob B Khurgin Jon D Peters John E Bowers

In this paper we demonstrate highly linear Mach-Zehnder interferometer modulators utilizing heterogeneous integration on a Si substrate (HS-MZM). A record high dynamic range was achieved for silicon devices, obtained using hybrid III-V/Si phase modulation sections and single drive push-pull operation, demonstrating a spurious free dynamic range (SFDR) of 112 dB∙Hz2/3 at 10 GHz, compa...

Journal: :Physical review letters 2010
Petr M Anisimov Gretchen M Raterman Aravind Chiruvelli William N Plick Sean D Huver Hwang Lee Jonathan P Dowling

We study the sensitivity and resolution of phase measurement in a Mach-Zehnder interferometer with two-mode squeezed vacuum (n photons on average). We show that superresolution and sub-Heisenberg sensitivity is obtained with parity detection. In particular, in our setup, dependence of the signal on the phase evolves n times faster than in traditional schemes, and uncertainty in the phase estima...

Journal: :Optics letters 2011
Christian Blum Christian Wolff Kurt Busch

We present a Wannier-function-based time-domain method for photonic-crystal integrated optical circuits. In contrast to other approaches, this method allows one to trade CPU time against memory consumption and therefore is particularly well suited for the treatment of large-scale systems. As an illustration, we apply the method to the design of a photonic-crystal-based sensor, which utilizes a ...

2012
Sanmukh Kaur

By exploiting nonlinear effects in a semiconductor optical amplifier, different functionalities for all-optical digital signal processing are implemented. In particular we demonstrate the logic functions of integrated addition-subtraction and demultiplexing. The all-optical realizations are based on semiconductor optical amplifier (SOA) and Mach–Zehnder interferometer (MZI), which represent one...

Journal: :The Review of scientific instruments 2011
Tien Tjuen Ng Darwin Gosal Antía Lamas-Linares Christian Kurtsiefer

A bulk-optics, polarization-independent phase shifter for photonic quantum information applications is demonstrated. The device is based on a transverse electro-optic modulator in a Sagnac-type loop containing Faraday rotators. This direction-dependent polarization rotation in the loop is combined with a Mach-Zehnder interferometer to form an optical switch with an on/off contrast of 96% and a ...

2016
Tatevik Chalyan Romain Guider Laura Pasquardini Manuela Zanetti Floris Falke Erik Schreuder Rene G. Heideman Cecilia Pederzolli Lorenzo Pavesi

In this work, we present a study of Aflatoxin M1 detection by photonic biosensors based on Si₃N₄ Asymmetric Mach-Zehnder Interferometer (aMZI) functionalized with antibodies fragments (Fab'). We measured a best volumetric sensitivity of 10⁴ rad/RIU, leading to a Limit of Detection below 5 × 10(-7) RIU. On sensors functionalized with Fab', we performed specific and non-specific sensing measureme...

2012
Yong-Hwan Kwon

waveguide (BWG)-based polarization beam splitter (PBS) in a Mach-Zehnder interferometer (MZI) configuration and analyze the structure-dependent or polarization-dependent phase difference, using a delay-line MZI (DL-MZI). We fabricate the DL-MZI using silica-based planar lightwave circuit technology and, using the DL-MZI, demonstrate the ability to optimize a PBS by measuring the birefringence o...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید