نتایج جستجو برای: maximum stress finite

تعداد نتایج: 958268  

2013
Muhammad Qasim Jae Taek Hong Raghu N. Natarajan Howard S. An

OBJECTIVE The offset connector can allow medial and lateral variability and facilitate intralaminar screw incorporation into the construct. The aim of this study was to compare the biomechanical characteristics of C7 intralaminar screw constructs with and without offset connector using a three dimensional finite element model of a C6-7 cervical spine segment. METHODS Finite element models rep...

Journal: :Journal of applied biomechanics 2012
Kadir Firidinoğlu Suna Toksavul Muhittin Toman Mehmet Sarikanat Ibrahim Nergiz

The purpose of this study was to compare the fracture resistance and fracture mode of single implant-zirconium coping combinations using zirconium and titanium abutments and to analyze the stress distribution pattern using three-dimensional finite elements analysis. Twenty implants with titanium and zirconium abutments were randomly divided into two groups (n = 10) and into resin blocks. Zircon...

Kermanshah, Hamid, Mirzaee, Mansoreh, Ranjbar Omrani, Ladan,

Evaluation of stress distribution in endodontically treated teeth, restored with post and crown by finite element analysis Dr. H. Kermanshah * - Dr. M. Mirzaee* - Dr. L. Ranjbar Omrani** *- Assistant Professor of Operative Dentistry Dept. - Faculty of Dentistry–Tehran University of Medical Sciences. **- Operative Dentistry Specialist. Background and Aim: Proper restoration of root canal treated...

2010
Chukwutoo Christopher Ihueze

This paper used the equation of the deflected axis of a beam to present procedures for solving one-dimensional functions that can be expressed in the form of Poisson equation. The equation of the deflected axis of a beam was solved for deflection for GRP composite component by Finite Element Method (FEM) using integrated FEM-Galerki approach to derive the finite elements equations. The critical...

Journal: :Circulation 1993
G C Cheng H M Loree R D Kamm M C Fishbein R T Lee

BACKGROUND Although rupture of an atherosclerotic plaque is considered to be the cause of most acute coronary syndromes, the mechanism of plaque rupture is controversial. METHODS AND RESULTS To test the hypothesis that plaque rupture occurs at sites of high circumferential stress in the diseased vessel, the distribution of stress was analyzed in 24 coronary artery lesions. Histological specim...

Journal: :The International journal of oral & maxillofacial implants 2012
Bruno Salles Sotto-Maior Plinio Mendes Senna Wander Jose da Silva Eduardo Passos Rocha Altair Antoninha Del Bel Cury

PURPOSE The aim of this study was to assess the contributions of some prosthetic parameters such as crown-to-implant (C/I) ratio, retention system, restorative material, and occlusal loading on stress concentrations within a single posterior crown supported by a short implant. MATERIALS AND METHODS Computer-aided design software was used to create 32 finite element models of an atrophic poste...

Journal: :journal of dentistry, tehran university of medical sciences 0
sara koosha assisstant professor, department of prosthodontics, islamic azad university of medical science, branch of dentistry, tehran, iran. fatemeh sadat mirhashemi

tooth/implant supported fixed prostheses may present biomechanical design problems, as the implant is rigidly anchored within the alveolus, whereas the tooth is attached by the periodontal ligament to the bone allowing movement. many clinicians prefer tooth/implant supported fixed prosthesis designs with rigid connectors. however, there are some doubts about the effect of attachment placement i...

2013
Saeed Raoofi Maryam Khademi Reza Amid Mahdi Kadkhodazadeh Mohammad Reza Movahhedi

Background and aims. The aim of this study was to determine the stress patterns within an implant and the effect of different types of connections on load transfer. Materials and methods. Three different types of implant-abutment connections were selected for this study. Sample A: 1.5-mm deep internal hex corresponding to a lead-in bevel; sample B: a tri-channel internal connection; and sample ...

2011
Xufeng Wang Yonghua Sun Shaohui Ma Wei Wang Jungang Wang Xuejun Zhang

In this paper the mechanical analysis of the film picking forks roller tooth in field -cleaning machine was done. A finite element analysis model was built and used by the non-linear finite element analysis method. It is obtained from the result of post-processing calculation and analysis that according to the Fourth Strength Theory, the maximum equivalent stress on the pole tooth root under th...

Javad Jafari Fesharaki, Omid Rejali Seyed Ghasem Madani

Distortion and deformation of tubes during machining operations are very important. In this study, a tube used in magnetic drum separator under concentrated load (machining load) is considered. Using finite element simulation, deformities and their dependence on parameters such as the thickness of the tube and the place of concentrated force are observed and predicted. To compare and confirm th...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید