نتایج جستجو برای: multileaf collimator

تعداد نتایج: 3034  

Journal: :Japanese Journal of Radiological Technology 2021

Purpose The purpose was to study comparative evaluation of calculated dose distribution by X-ray Voxel Monte Carlo (XVMC) for calculation in Acuros XB (AXB). commissioning and head neck volumetric modulated arc therapy (VMAT) clinical cases were compared AXB Eclipse XVMC Monaco. Methods For TrueBeam at 6 MV, we the simple rectangle, heterogeneity correction, multileaf collimator (MLC) character...

Journal: :International journal of radiation oncology, biology, physics 2006
Paul J Keall Herbert Cattell Damodar Pokhrel Sonja Dieterich Kenneth H Wong Martin J Murphy S Sastry Vedam Krishni Wijesooriya Radhe Mohan

PURPOSE Dynamically compensating for target motion during radiotherapy will increase treatment accuracy. A laboratory system for real-time target tracking with a dynamic MLC has been developed. In this study, the geometric accuracy limits of this DMLC target tracking system were evaluated. METHODS AND MATERIALS A motion simulator was programmed to follow patient-derived tumor motion paths, pa...

Journal: :International journal of radiation oncology, biology, physics 2011
Paul J Keall Amit Sawant Byungchul Cho Dan Ruan Junqing Wu Per Poulsen Jay Petersen Laurence J Newell Herbert Cattell Stine Korreman

PURPOSE Intensity-modulated arc therapy (IMAT) is attractive because of high-dose conformality and efficient delivery. However, managing intrafraction motion is challenging for IMAT. The purpose of this research was to develop and investigate electromagnetically guided dynamic multileaf collimator (DMLC) tracking as an enabling technology to treat moving targets during IMAT. METHODS AND MATER...

Journal: :Physics in medicine and biology 2002
Jeffrey V Siebers Paul J Keall Jong Oh Kim Radhe Mohan

Monte Carlo (MC) algorithms are recognized as the most accurate methodology for patient dose assessment. For intensity-modulated radiation therapy (IMRT) delivered with dynamic multileaf collimators (DMLCs), accurate dose calculation, even with MC, is challenging. Accurate IMRT MC dose calculations require inclusion of the moving MLC in the MC simulation. Due to its complex geometry, full trans...

2010
J. W. Oosterhuis

Cover: Generation of an intensity modulated field by using dynamic multileaf collimation.

Journal: :Medical physics 2003
R George P J Keall V R Kini S S Vedam J V Siebers Q Wu M H Lauterbach D W Arthur R Mohan

Respiratory motion during intensity modulated radiation therapy (IMRT) causes two types of problems. First, the clinical target volume (CTV) to planning target volume (PTV) margin needed to account for respiratory motion means that the lung and heart dose is higher than would occur in the absence of such motion. Second, because respiratory motion is not synchronized with multileaf collimator (M...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید