نتایج جستجو برای: mv photon beam
تعداد نتایج: 199565 فیلتر نتایج به سال:
Introduction Radiotherapy planning systems require many percentage depth dose (PDD) and profile measurements and there are various dosimeters that can be used to obtain these scans. As dose perturbation is particularly troublesome in smaller photon fields, using a low-perturbation, unshielded electron field diode (EFD) in these fields is of interest. The aim of this work was to investigate the ...
In this study, we assessed the differences in the dose distribution of a 4 MV photon beam among different calculation algorithms: the Acuros XB (AXB) algorithm, the analytic anisotropic algorithm (AAA), and the pencil beam convolution (PBC) algorithm (ver. 11.0.31), in phantoms and in clinical intensity-modulated radiation therapy (IMRT) plans. Homogeneous and heterogeneous, including middle-, ...
Background: Prediction of the absorbed dose in irradiated volume plays an important role in the outcome of radiotherapy. Application of small fields for radiotherapy of thorax makes the dose calculation process inaccurate due to the existence of electronic disequilibrium and intrinsic deficiencies in dose calculation algorithms. To study the lung absorbed dose in radiotherapy with smal...
PURPOSE Positioning verification is usually performed with treatment beam (MV) portal images (PI) using an electronic portal imaging device (EPID). A new alternative is the use of a low energy photon source (kV) and an additional EPID mounted to the accelerator gantry. This system may be used for PI or--with rotating gantry--as cone-beam CT (CBCT). The dose delivered to the patient by different...
This investigation aimed to measure and commission small unflat photon beams using the detectors described in our previous study10. Furthermore, dosimetric parameters of small-field flat were compared provide a better interpretation beam energy spectrum. The TrueBeam linear accelerator (TrueBeam LINAC, Varian Medical Systems) was employed this study. 10 6 MV used output factor, depth dose, prof...
Because of the adverse effects of ionizing radiation on fetuses, prior to radiotherapy of pregnant patients, fetal dose should be estimated. Fetal dose has been studied by several authors in different depths in phantoms with various abdomen thicknesses (ATs). In this study, the effect of maternal AT and depth in fetal dosimetry was investigated, using peripheral dose (PD) distribution evaluatio...
abstractbackgrounds: md-55-2 is one of the radiochromic film models with the sensitivity suitable for dose measurements ranging from 5 to 100 gy. however, this lower limit makes the film impractical for its applications in many areas such as brachytherapy source dosimetry.materials and methods: in this project, the useful range of the film has been extended by using a multilayer film technique...
The GEANT4-based GATE Monte Carlo (MC) platform was initially focused on PET and SPECT simulations. The new release v6.0 (February 2010) proposes new tools dedicated for radiation therapy simulations. In this work, we investigated some part of this extension and proposed a general methodology for Linac simulations. Details of the modeling of a 6 MV photon beam delivered by an Elekta Precise Lin...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید