نتایج جستجو برای: peak detector

تعداد نتایج: 198135  

2009
S. C. Lee E. Plis S. Krishna

The mid-infrared transmission through a 3.7 mm period, twodimensional sub-wavelength Au metallic hole array integrated on a GaSb/InAs strained layer superlattice nBn photodetector is measured. The surface plasmon-polariton excitation on the Au film induces a peak transmission in the 200 K detector response at 4.2 mm. This transmission is enhanced threefold by the insertion of a SiNx layer betwe...

Journal: :Optics letters 2013
Colin J R Sheppard Shalin B Mehta Rainer Heintzmann

The effect of detector array size on resolution and signal collection efficiency of image scanning microscopy based on pixel reassignment is studied. It is shown how the method can also be employed if there is a Stokes shift in fluorescence emission wavelength. With no Stokes shift, the width of the point spread function can be sharpened by a factor of 1.53, and its peak intensity increased by ...

2001
M. Casarsa V. Casavola G. Cataldi F. Ceradini F. Cervelli F. Cevenini G. Chiefari G. De Robertis P. De Simone G. De Zorzi A. Farilla G. Felici A. Ferrari M. L. Ferrer G. Finocchiaro P. Santangelo E. Santovetti G. Saracino R. D. Schamberger G. W. Yu P. F. Zema Y. Zhou

We present a study of the reaction e+e−→π+π−γ at the φ peak with the KLOE detector at the φ–factory DAΦNE. This reaction allows us to obtain the cross section for e+e−→π+π− from the ee center-of-mass energy W = mφ = 1019 MeV down to threshold, i.e.2mπ < Mππ < mφ. This is called radiative return. The status of the analysis and preliminary results on the invariant mass spectrum of the two-pion-st...

2001
G. Mancinelli

We report on preliminary results of searches for penguin mediated B decays based on 20.7 fb −1 of data collected at the Υ (4S) peak with the BABAR detector at PEP-II. The following branching fractions have been measured: B(B + → φK +) = (7.7 −5.6 ± 1.7) × 10 −6 , where the first error is statistical and the second systematic. For several other modes we report upper limits on their branching fra...

2001
G Mancinelli

We report on preliminary results of searches for penguin mediated B decays based on 20.7 fb −1 of data collected at the Υ (4S) peak with the BABAR detector at PEP-II. The following branching fractions have been measured: B(B + → φK +) = (7.7 −5.6 ± 1.7) × 10 −6 , where the first error is statistical and the second systematic. For several other modes we report upper limits on their branching fra...

Journal: :Environmental Science & Technology 2007

Journal: :Proceedings of the American Mathematical Society 1997

2009
P. U. E. Onyisi J. L. Rosner J. P. Alexander D. G. Cassel J. E. Duboscq R. Ehrlich L. Fields R. S. Galik L. Gibbons R. Gray S. W. Gray D. L. Hartill B. K. Heltsley D. Hertz J. M. Hunt J. Kandaswamy D. L. Kreinick V. E. Kuznetsov J. Ledoux H. Mahlke-Krüger D. Mohapatra J. R. Patterson D. Peterson D. Riley A. Ryd A. J. Sadoff X. Shi S. Stroiney W. M. Sun T. Wilksen S. B. Athar J. Yelton P. Rubin N. Lowrey S. Mehrabyan M. Selen J. Wiss R. E. Mitchell M. R. Shepherd D. Besson T. K. Pedlar D. Cronin-Hennessy K. Y. Gao J. Hietala Y. Kubota T. Klein R. Poling A. W. Scott P. Zweber S. Dobbs Z. Metreveli K. K. Seth B. J. Y. Tan A. Tomaradze J. Libby L. Martin A. Powell G. Wilkinson H. Mendez J. Y. Ge D. H. Miller V. Pavlunin B. Sanghi I. P. J. Shipsey B. Xin G. S. Adams D. Hu B. Moziak J. Napolitano K. M. Ecklund Q. He J. Insler H. Muramatsu C. S. Park E. H. Thorndike F. Yang M. Artuso S. Blusk S. Khalil J. Li R. Mountain K. Randrianarivony N. Sultana T. Skwarnicki S. Stone J. C. Wang L. M. Zhang G. Bonvicini D. Cinabro M. Dubrovin A. Lincoln M. J. Smith P. Naik J. Rademacker D. M. Asner K. W. Edwards J. Reed A. N. Robichaud G. Tatishvili E. J. White R. A. Briere

We have studied the leptonic decay D+ s → τ ντ , via the decay channel τ + → eνeν̄τ , using a sample of tagged D+ s decays collected near the D ∗± s D ∓ s peak production energy in e +e− collisions with the CLEO-c detector. We obtain B(D+ s → τ ντ ) = (5.30± 0.47± 0.22)% and determine the decay constant fDs = (252.5±11.1±5.2) MeV, where the first uncertainties are statistical and the second are ...

Journal: :iranian journal of allergy, asthma and immunology 0
m.ii. boskabady m. ilosaini

for better management of asthma it is essential that patients adjust their treatment according to the medical plan developed by the health care professionals. to achieve this goal, patients should assess the severity of their disease regularly. the purpose of this study was to determine the effect of regular measurement of peak expiratory flow and patient education on self management of asthma....

2004
M. Hewitson G. Heinzel J. R. Smith

GEO 600 is a dual-recycled interferometric gravitational wave detector which uses advanced optical techniques to achieve its design sensitivity. The peak response of GEO is tunable over a range of frequencies within the detection band of the instrument. The accurate calibration of the detector is an essential step in preparing the data for distribution to the various analysis groups in the comm...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید