نتایج جستجو برای: power system harmonics
تعداد نتایج: 2587527 فیلتر نتایج به سال:
Numerical methods for the computation of harmonic propagation and distortion differ in the manner in which they represent the harmonic sources and the system impedance. Iterative methods (e.g. harmonic load flow) use a phasor representation of these parameters. Time domain methods, on the other hand, use a time representation of the system elements and the harmonic sources. Thus, they are gener...
This paper deals with the analysis of implementing Sinusoidal Pulse Width Modulation (SPWM) controlling strategy in three phase Uninterruptible Power Supply (UPS) system operating under highly nonlinear load. The conventional type of controller is not enough to reduce harmonics in the system under highly nonlinear load in high power system. The SPWM based method is applied to the UPS system to ...
This paper presents detailed modeling and simulation of a compensator for Load balancing and harmonics Compensation based on a five-level cascaded H-bridge multilevel voltage source inverter. This type of compensator, which is installed in parallel with the load, is usually referred to as the shunt active power filters (APF). Nowadays use of high voltage non-linear loads are widely used in indu...
In this paper, for bus voltage control and to reduce power system harmonics, the active filtering technique is used in the mechanism of wind turbine control. Here a grid-connected doubly fed induction generator (DFIG) is considered in a wind turbine. In addition to harmonics that are related to the DFIG, a nonlinear load is also added to the system to simulate loads that produce more harmonics....
The Shunt Active Power Filter (SAPF) is one of the key controllers in Flexible Alternating Current Transmission System (FACTS) to control the transmission line voltage and can be used in Power System (PS) to enhance the power quality. This paper compares performance of Cascaded Five-Level Inverter (CFLI) based SAPF in PS with PI, Fuzzy and Neurofuzzy controller. Making use of the CFLI has benef...
This paper deals with the analysis of implementing Sinusoidal Pulse Width Modulation (SPWM) controlling strategy in three phase Uninterruptible Power Supply (UPS) system operating under highly nonlinear load. The conventional type of controller is not enough to reduce harmonics in the system under highly nonlinear load in high power system. The SPWM based method is applied to the UPS system to ...
This paper presents an overview of different control methods which are applied on Shunt Active Power Filter to achieve harmonics reduction and power factor improvement. In recent decades, the world has seen an expansion in the use of non-linear loads. These loads draw a non-sinusoidal current from the source and distribute them throughout the system. As a result the power quality degrades. Ther...
Power Quality is an essential aspect for reliable operation of power grid including Photovoltaic based generation. This paper focuses on real time problem of injection of harmonics and resonance into power network having 5MW solar plant. The solar plant includes 10 inverters each of 500KW connected to 33kV bus. Power produced by plant is explored via 4km cable at 220kV, where conventional plant...
A digital fast feedback system for beam energy and position stabilization at the target of the CEBAF accelerator is capable of suppressing beam motion in the frequency band from 0 to 80 Hz and also performs narrow band suppression at the first twelve power line harmonics. The system utilizes two VME computers and runs at a 2.4 kHz sampling rate. The numerical algorithm is based on a recursive d...
چکیده ندارد.
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید