نتایج جستجو برای: reinforced concrete beam
تعداد نتایج: 216986 فیلتر نتایج به سال:
Abstract: The performance of corroded reinforced concrete (RC) beams strengthened with externally bonded carbon fiber reinforced polymer (CFRP) materials may be affected by a weak interface caused either by defective bonding between the new and old concrete in the case of cover replacement or by expansive cracks in the case of direct application. To investigate this effect, thirteen strengthene...
This paper describes the detection and identification of cracking severity in a reinforced concrete beam using modal data. Experimental modal test was performed on the beam before and after application of load of increasing intensity to induce a single crack at a fixed location. Modal parameters extracted were categorised into hvo groups, namely local response parameter (mode shape data) and gl...
Tension stiffening is a characteristic behavior of reinforced concrete (RC) beams which is directly affected by the bond-slip property of steel bar and concrete interfaces. A beam strengthened with a near-surface mounted (NSM) technique would be even more affected by tension stiffening, as the NSM reinforcement also possess a bond-slip property. Yet assessing how much the tension stiffening of ...
Full Scale Reinforced Concrete Beam-Column Joints Strengthened with Steel Reinforced Polymer Systems
A large share of reinforced concrete (RC) framed buildings is provided with wide beams being a type of beam allowing greater freedom in the architectural arrangement of interiors, beyond further advantage due to fewer formworks needed during the construction. Nevertheless, little attention has been devoted to the seismic vulnerability of this kind of framed RC buildings as well as to the study ...
The article shows the effect of torsional rigidity of beam elements onto spatial work of bridges, floorings and other plate-ribbed systems It is shown that, in determining the torsional rigidity using existing methods it is necessary to have spatial spiral cracks, but torsional rigidity when normal cracks is not researched. A method is described for determining the torsional rigidity of reinfor...
The present study investigates the force transfer mechanisms for open hoop fiber reinforced plastic (FRP) strips attached at reinforced concrete (R/C) beams with or without anchorage. These open hoop FRP strips are utilized in R/C beams that are in need of shear capacity upgrade. This type of retrofitting is necessary for R/C structures designed with less stringent seismic loading conditions th...
Brillouin scattering-based distributed optical fiber (OF) sensing technique presents advantages for concrete structure monitoring. However, the existence of spatial resolution greatly decreases strain measurement accuracy especially around cracks. Meanwhile, the brittle feature of OF also hinders its further application. In this paper, the distributed OF sensor was firstly proposed as long-gaug...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید