نتایج جستجو برای: reinforced concrete column

تعداد نتایج: 179189  

2018
Devon S Ellis Habib Tabatabai Azam Nabizadeh

The use of fiber reinforced polymer (FRP) bars in reinforced concrete members enhances corrosion resistance when compared to traditional steel reinforcing bars. Although there is ample research available on the behavior of FRP bars and concrete members reinforced with FRP bars under elevated temperatures (due to fire), there is little published information available on their post-fire residual ...

2012
Matthew Smith Matt E. Thomas

Synopsis: The structural design for the East Addition to the St. Cloud Hospital facility in central Minnesota incorporated punching shear and cracked section design criteria that are not currently specified in ACI 318-05. The complexity of the column layout and shallow floor-to-floor spacing were the primary reasons for choosing a twoway 12 in. (300 mm) reinforced concrete flat slab for the 450...

2008
Jie Xiong Youjiang Wang

There is a growing need for the rehabilitation, repair, and upgrading of concrete structures such as bridges and buildings. The repair or rehabilitation of reinforced concrete structures often offers a lower cost alternative to rebuilding, and it is traditionally achieved by bonding steel plates to the tensile face of a reinforced concrete member. The shear strength can be enhanced with plates ...

Journal: :civil engineering infrastructures journal 0
arash mohammadi farsani lecture, department of civil engineering, farsan branch, islamic azad university, farsan, iran behrooz keshtegar assistant professor, department of civil engineering, university of zabol, p.o.box: 9861335-856, zabol, iran.

steel corrosion of bars in concrete structures is a complex process which leads to the reduction of the cross-section bars and decreasing the resistance of the concrete and steel materials. in this study, reliability analysis of a reinforced concrete beam with corrosion defects under the distributed load was investigated using the enhanced hasofer-lind and rackwitz-fiessler (ehl-rf) method base...

2012
M. Fernández Ruiz

The ultimate strength of reinforced concrete slabs is frequently governed by the punching shear capacity, which may be increased with addition of traditional fitments such as reinforcing steel, headed studs or shear heads. In addition to these traditional methods of strengthening against punching, steel fibre reinforcement has proved to be an effective and viable alternative. The addition of fi...

2013
Amir M. Alani

This paper in essence presents comparative experimental data on the mechanical performance of steel and synthetic fibre-reinforced concrete under compression, tensile split and flexure. URW1050 steel fibre and HPP45 synthetic fibre, both with the same concrete design mix, have been used to make cube specimens for a compression test, cylinders for a tensile split test and beam specimens for a fl...

Journal: :international journal of civil engineering 0
a. kaveh iust a. shakouri mahmud abadi bhrc

cost optimization of the reinforced concrete cantilever soil retaining wall of a given height satisfying some structural and geotechnical design constraints is performed utilizing harmony search and improved harmony search algorithms. the objective function considered is the cost of the structure, and design is based on aci 318-05. this function is minimized subjected to design constraints. a n...

2004
X. Q. Zhu

The interface between concrete and steel in reinforced concrete governs the interaction between the two types of materials under loading. When the interface is seriously damaged, such that a macro-crack is formed, de-bonding takes place or large slip occurs, and the load-transferring capacity of the interface will drop dramatically. In this study, a vibration-based method is presented to detect...

Journal: :Journal of Renewable Materials 2022

The use of fibre-reinforced polymer (FRP) to confine concrete columns improves the strength and ductility by reducing passive lateral confinement pressure. Many numerical analytical formulations have been proposed in literature describe compressive behaviour FRP confined under both monotonic cyclic loads. However, effect a stress/strain level has not well defined because lack well-defined strat...

Enhancement of the response of reinforced concrete (RC) beams using fiber-reinforced polymer (FRP) reinforcement bars has become a popular structural technique over the past two decades due to the well-known advantages of FRP composites including their high strength-to-weight ratio and excellent corrosion resistance. Thisstudy presents n...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید