نتایج جستجو برای: selective membrane electrode
تعداد نتایج: 631334 فیلتر نتایج به سال:
Polymer membrane electrodes operated by pulsed chronopotentiometry have recently been introduced to replace traditional ion-selective electrodes for a number of applications. While ion-selective electrodes for the polycation protamine have been reported, for instance, a pulsed chronopotentiometric readout mode (called here pulstrode) provides improved stability and reproducibility while exhibit...
Three novel phenyltelluroalkoxyl functionalized tweezer-like calix[4]arenes 6-8 and two monophenyltelluropropoxyl functionalized calix[4]arenes 10 (cone conformer) and 12 (partial cone conformer) were synthesized and characterized. They are good Ag(+)-selective ionophores in ion-selective electrodes evaluated by electromotive force measurements of polymer membrane electrodes. The tweezer-like i...
The potentiometric response of electrodes is described, including: (1) Nernstian response to activity change due to an altered concentration of the analyte ion, and (2) Nernstian response to activity change caused by different solvents. In order to ensure the reliability of the data obtained in this study, the following three steps were taken: (i) a comparison of electrode potentials between a ...
The cobaltabisdicarbollide anion is used as a new material able to generate an ion-pair complex used for PVC membrane ion selective electrodes.
A split-stream flow-injection analysis system is described for simultaneous determination of glucose and L-glutamine in serum-free hybridoma bioprocesses media. Amperometric measurement of glucose is based on anodic oxidation of hydrogen peroxide produced by immobilized glucose oxidase within a triple layer membrane of an integrated flow-through glucose-selective biosensor. Determination of L-g...
In recent years, ion-selective electrodes based on polymer membranes have been shown to exhibit detection limits that are often in the nanomolar concentration range, and thus drastically lower than traditionally accepted. Since potentiometry is less dependent on scaling laws that other established analytical techniques, their performance in confined sample volumes is explored here. Solid-contac...
This paper reports on the development of a micro-potentiometric sensor based on external microelectrodes introduced into a microchip. We miniaturized reference and ion-selective electrodes (ISEs) and embedded them into a plastic (PDMS) microchip; the miniaturization of ISE was attained by using a monolithic capillary-based membrane. This sensor was applied to the detection of alkali ions (Na+, ...
fluoride is recognized as an effective agent for dental caries prevention. generally, the main source of fluoride intake is drinking water. in this study, fluoride content in 18 commercial brands of bottled waters was investigated. six samples from each batch of 18 iranian commercial brands of bottled waters were supplied. the fluoride content of samples was analyzed by fluoride ion selective e...
2-amino-n-benzthioazolyl benzamide (abtb) was synthesized, characterized and used for thefabrication of a potentiometric sensor for cu2+ metal ions. the electrode exhibits linear response to cu(ii) over a wide concentration range (4.79×10 -8 – 1.85×10 -1 m) with nernstian slope of 30 ± 1.5 mvper decade. the electrode can be used in the ph range from 2 to 9. it has a fast response time of about1...
The group of Egorov has recently proposed an elegant method to determine unbiased selectivity coefficients of ion-selective electrodes (Egorov et al. Anal. Chem. 2014, 86, 3693). Once the electrode is exposed to a solution containing only interfering ions, the time-dependent experimental selectivity coefficients are plotted as a function of the inverse fourth root of time and extrapolated to ze...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید