نتایج جستجو برای: spiral inductors

تعداد نتایج: 33613  

Journal: :Facta universitatis - series: Electronics and Energetics 2005

Journal: :IEEJ Transactions on Fundamentals and Materials 2006

Journal: :IEEE Transactions on Microwave Theory and Techniques 2017

2009
J. Czogalla Jieli Li C. R. Sullivan Jens Czogalla Charles R. Sullivan

A set of four coupled inductors is applied to a four-phase interleaved 1 kW bi-directional 14 V to 42 V dc/dc converter for automotive applications. The coupled-inductor structure is optimized, and the performance is examined through simulations and experimental measurements. Although coupled inductors offer bigger advantages in applications that require fast transient response, they also have ...

Journal: :iranian journal of radiology 0
saeed naghibi department of radiology, faculty of medicine, mashhad branch, islamic azad university, mashhad, iran; department of radiology, faculty of medicine, mashhad branch, islamic azad university, mashhad, iran. tel: +98-9151158630, fax: +98-5137613248 sirous seifirad department of radiology, faculty of medicine, mashhad branch, islamic azad university, mashhad, iran mahboobeh adami dehkordi department of radiology, faculty of medicine, mashhad branch, islamic azad university, mashhad, iran sasan einolghozati department of radiology, faculty of medicine, mashhad branch, islamic azad university, mashhad, iran nafiseh ghaffarian eidgahi moghadam department of radiology, faculty of medicine, mashhad branch, islamic azad university, mashhad, iran amir akhavan rezayat department of radiology, mashhad university of medical sciences, mashhad, iran

conclusion spiral-ct scan is superior to conventional ct in the diagnosis of lesions in com before operation. it can be used for detailed evaluation of ossicular chain in such patients. objectives this study was performed to compare the findings of three-dimensional reconstructed spiral and conventional ct scan of ossicular chain study in patients with com. patients and methods fifty patients e...

2004

* D Abstract --Lossless broad-band microwave active inductors for generalpurpose use in microwave circuits are proposed and their characteristics are discussed. These active inductors are composed of a common-source cascode FET and a feedback FET, and operate in a wide frequency range with very low series resistance. A maximum Q factor of 65 is obtained. Theoretically, it can reach infinity. Fu...

2012
Nikola Jeranče Nataša Samardžić Dragana Vasiljević Goran Stojanović

In this paper, electromagnetic modeling of capacitors and inductors for printed electronic circuits is studied. Capacitors are successfully modeled by two-dimensional finite element software. Capacitive sensor for chemical detection is proposed and tested in water. Inductors are modeled by the integrating through the currents and obtained results have been compared with 3D finite element method...

1999
Vishay Dale

The scope of this application note is to define the terminology associated with inductors and their applications. Some of these terms are listed in the component data sheets. Many terms go beyond the specification of inductors. These terms describe issues associated with inductor design and performance, magnetic materials and theory and applications. A thorough understanding of these terms and ...

2004
Ming-Da Tsai Huei Wang Chih-Ping Chao

A fully-integrated 4.3-7 GHz CMOS low-voltage wideband low-noise amplifier with helical inductors has been demonstrated in this paper. The CMOS LNA, operating at a supply voltage as low as 1 V, achieves a small signal gain of 14 dB and 3-dB bandwidth from 4.3 to 7 GHz. The minimum noise figure is 2.9 dB at 6 GHz. With the benefits of helical inductors, the total effective chip size is only 0.2 mm.

1999
Luca Daniel Charles R. Sullivan Seth R. Sanders

Possible configurations for microfabricated inductors are considered. Inductance can be set by adjusting permeability through control of anisotropy of a permalloy core or via a patterned quasi-distributed gap. A design methodology based on a simple model is proposed. A more accurate model and a numerical optimization are also developed. Design examples for 5and 10-MHz buck converters and 2.5-MH...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید