نتایج جستجو برای: spiral plate heat exchanger

تعداد نتایج: 309703  

Journal: :international journal of advanced design and manufacturing technology 0
yashar bashirzadeh islamic azad university, science and research branch nariman ashrafi

the present experimental study reports on enhancement of heat transfer by addition of nanoparticles to the working fluid of commercial swimming pool heat exchangers under laminar flow condition. three different concentrations of titanium dioxide nanoparticles were added to the water as working fluid of a typical forced convective heat exchanger used to transfer heat to public swimming pools. th...

Journal: :پژوهش نفت 0

in this study. optimum allocation of heat transfer inventory for heat exchangers in a refrigeration system with specified power input or cooling capacity. and for a heat pump with specified heating capacity is investigated. the ratio of hot- to cold-end conductance unit cost ratio. g.was considered in the analysis as an additional variable of considerable importance to the designer summarized e...

Journal: :Oil & Gas Science and Technology – Revue d’IFP Energies nouvelles 2021

For insuring the safe operation of LNG heat exchanger in Emergency Stop Operation Process (ESOP), a numerical method is proposed to investigate stress Plate-Fin Structures (PFS) that. The relationship between PFS and ESOP analyzed exchanger. results will be obtained that maximum equivalent greater at initial stage than last when HMR pressure more 5 MPa. increases with equilibrium temperature 18...

Journal: :Korean Journal of Air-Conditioning and Refrigeration Engineering 2012

Journal: :Korean Journal of Air-Conditioning and Refrigeration Engineering 2016

Journal: :Chemie Ingenieur Technik 2023

Infrared thermography of brazed plate heat exchangers for evaporators and condensers recently was used to quantify maldistribution. With the knowledge secondary fluids transfer coefficient a given distribution, local primary fluid (refrigerant) its distribution channels can be calculated. A sensitivity analysis shows ± 10 % difference surface temperature wall center at expected ratios coefficie...

Journal: :Eureka: Physics and Engineering 2023

This experimental study aims to investigate and analyze the performance of a Water-Air Heat Exchanger that functions as passive cooling in building ventilation system tropics. Before being blown into room, high-temperature outdoor air will be passively cooled by lower-temperature water. Air driven an Inline Duct Fan with constant mass flow rate 4.68 cubic meters per minute flows through PVC hos...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید